41-19
Cisco ME 3400 Ethernet Access Switch Software Configuration Guide
OL-9639-07
Chapter 41 Configuring Ethernet OAM, CFM, and E-LMI
Setting Up and Configuring Ethernet OAM
Step 4
ethernet oam link-monitor symbol-period
{
threshold
{
high
{
high symbols
|
none
} |
low
{
low-symbols
}} |
window
symbols
}
Note
Repeat this step to configure both high and
low thresholds.
(Optional) Configure high and low thresholds for an
error-symbol period that trigger an error-symbol period
link event.
•
Enter
threshold high
high-symbols
to set a high
threshold in number of symbols. The range is 1 to
65535. The default is
none
.
•
Enter
threshold
high none
to disable the high
threshold if it was set. This is the default.
•
Enter
threshold low
low-symbols
to set a low
threshold in number of symbols. The range is 0 to
65535. It must be lower than the high threshold.
•
Enter
window
symbols
to set the window size (in
number of symbols) of the polling period. The range is
1 to 65535 symbols.
Step 5
ethernet oam link-monitor frame
{
threshold
{
high
{
high-frames
|
none
} |
low
{
low-frames
}} |
window
milliseconds
}
Note
Repeat this step to configure both high and
low thresholds.
(Optional) Configure high and low thresholds for error
frames that trigger an error-frame link event.
•
Enter
threshold high
high-frames
to set a high
threshold in number of frames. The range is 1 to
65535. The default is
none
.
•
Enter
threshold
high none
to disable the high
threshold if it was set. This is the default.
•
Enter
threshold low
low-frames
to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
•
Enter
window
milliseconds
to set the a window and
period of time during which error frames are counted.
The range is 10 to 600 and represents the number of
milliseconds in multiples of 100. The default is 100.
Step 6
ethernet oam link-monitor frame-period
{
threshold
{
high
{
high-frames
|
none
} |
low
{
low-frames
}} |
window
frames
}
Note
Repeat this step to configure both high and
low thresholds.
(Optional) Configure high and low thresholds for the
error-frame period that triggers an error-frame-period link
event.
•
Enter
threshold high
high-frames
to set a high
threshold in number of frames. The range is 1 to
65535. The default is
none
.
•
Enter
threshold
high none
to disable the high
threshold if it was set. This is the default.
•
Enter
threshold low
low-frames
to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
•
Enter
window
frames
to set the a polling window size
in number of frames. The range is 1 to 65535; each
value is a multiple of 10000 frames. The default is
1000.