Step 5
ethernet oam link-monitor frame
{
threshold
{
high
{
high-frames
|
none
} |
low
{
low-frames
}} |
window
milliseconds
}
(Optional) Configure high and low thresholds for error
frames that trigger an error-frame link event.
•
Enter
threshold high
high-frames
to set a high
threshold in number of frames. The range is 1 to
65535. You must enter a high threshold.
•
Enter
threshold
high none
to disable the high
threshold.
•
Enter
threshold low
low-frames
to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
•
Enter
window
milliseconds
to set the a window and
period of time during which error frames are counted.
The range is 10 to 600 and represents the number of
milliseconds in a multiple of 100. The default is 100.
Step 6
ethernet oam link-monitor frame-period
{
threshold
{
high
{
high-frames
|
none
} |
low
{
low-frames
}} |
window
frames
}
(Optional) Configure high and low thresholds for the
error-frame period that triggers an error-frame-period link
event.
•
Enter
threshold high
high-frames
to set a high
threshold in number of frames. The range is 1 to
65535. You must enter a high threshold.
•
Enter
threshold
high none
to disable the high
threshold.
•
Enter
threshold low
low-frames
to set a low threshold
in number of frames. The range is 0 to 65535. The
default is 1.
•
Enter
window
frames
to set the a polling window size
in number of frames. The range is 1 to 65535; each
value is a multiple of 10000 frames. The default is
1000.
Step 7
ethernet oam link-monitor frame-seconds
{
threshold
{
high
{
high-seconds
|
none
} |
low
{
low-seconds
}} |
window
milliseconds
}
(Optional) Configure frame-seconds high and low
thresholds for triggering an error-frame-seconds link event.
•
Enter
threshold high
high-seconds
to set a high
threshold in number of seconds. The range is 1 to 900.
You must enter a high threshold.
•
Enter
threshold
high none
to disable the high
threshold.
•
Enter
threshold low
low-frames
to set a low threshold
in number of frames. The range is 1 to 900. The default
is 1.
•
Enter
window
frames
to set the a polling window size
in number of frames. The range is 100 to 9000; each
value is a multiple of 100 milliseconds. The default is
1000.
Command
Purpose
Summary of Contents for ME 3400 Series
Page 40: ...Contents xl Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 ...
Page 44: ...xliv Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 Preface ...
Page 1138: ...Index IN 52 Cisco ME 3400 Ethernet Access Switch Software Configuration Guide OL 9639 07 ...