3-4
Installing Cisco Intrusion Prevention System Appliances and Modules 5.0
78-16124-01
Chapter 3 Installing IDS-4215
Accessories
Note
Only one PCI expansion slot can be used for the 4FE card. We recommend you install the 4FE card in
the lower PCI expansion slot.
Accessories
Warning
IMPORTANT SAFETY INSTRUCTIONS
This warning symbol means danger. You are in a situation that could cause bodily injury. Before you
work on any equipment, be aware of the hazards involved with electrical circuitry and be familiar
with standard practices for preventing accidents. Use the statement number provided at the end of
each warning to locate its translation in the translated safety warnings that accompanied this device.
Statement 1071
SAVE THESE INSTRUCTIONS
Warning
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
IDS-4215 accessories kit contains the following:
•
DB25F/RJ45F adaptor
•
DB9F/RJ45F adaptor
•
Rubber mounting feet
•
Rack mounting kit—screws, washers, and metal bracket
Steady state
50W
Maximum peak
65W
Maximum heat dissipation
410 BTU/hr, full power usage (65W)
Environment
Temperature
Ope41°F to +104°F (+5°C to +40°C)
Nonoperating -13°F to +158°F (-25°C to +70°C)
Relative humidity
Operating 5% to 95% (noncondensing)
Nonoperating 5% to 95% (noncondensing)
Altitude
Operating 0 to 9843 ft (3000 m)
Nonoperating 0 to 15,000 ft (4750 m)
Shock
Operating 1.14 m/sec (45 in./sec) 1/2 sine input
Nonoperating 30 G
Vibration
0.41 Grms2 (3-500 Hz) random input
Acoustic noise
54 dBa maximum
Table 3-3
IDS-4215 Specifications (continued)