7-15
Installing Cisco Intrusion Prevention System Appliances and Modules 5.0
78-16124-01
Chapter 7 Installing IDSM-2
Powering IDSM-2 Up and Down
Powering IDSM-2 Up and Down
You can remove and restore power to IDSM-2 through the switch CLI. This section describes how to
power IDSM-2 up and down through the switch CLI, and contains the following sections:
•
Catalyst Software, page 7-15
•
Cisco IOS Software, page 7-15
Catalyst Software
Once you power off IDSM-2, you must power it up through the switch CLI.
Note
The IDSM-2 CLI reset powerdown command performs a shut down, but does not remove power from
IDSM-2.
To power IDSM-2 up and down from the switch CLI, follow these steps:
Step 1
Log in to the console.
Step 2
Enter privileged mode:
console>
enable
Step 3
Power up IDSM-2:
console> (enable)
set module power up
module_number
Step 4
Power down IDSM-2:
console> (enable)
set module power down
module_number
Cisco IOS Software
Once you power off IDSM-2, you must power it up through the switch CLI.
Note
The IDSM-2 CLI reset powerdown command performs a shut down, but does not remove power from
IDSM-2.
To power IDSM-2 up and down from the switch CLI, follow these steps:
Step 1
Log in to the console.
Step 2
Enter configure terminal mode:
router#
configure terminal
Step 3
Power up IDSM-2:
router(config)#
power enable module
module_number