DSL Interface Cards
Connecting a DSL Interface Card to the Network
13
OL-12846-01
Warning
To comply with the Telcordia GR-1089 NEBS standard for electromagnetic compatibility and safety,
connect the HWIC-2SHDSL and HWIC-4SHDSL interface cards only to intra-building or unexposed
wiring or cable. The intra-building port(s) of the equipment or subassembly must not be metallically
connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use
as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 4) and
require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient
protection in order to connect these interfaces metallically to OSP wiring.
Figure 71
shows the
RJ-45
pin assignment.
Table 23
identifies the
RJ-45
signal assignment by pin.
Caution
Inserting an
RJ-11
connector into the Cisco HWIC-4SHDSL port may deform pins 1 and 8, which may
prevent solid contact between the connector and the plug in subsequent connections. If solid contact is
prevented, line -1 tip and line -3 ring will not work properly.
Figure 71
RJ-45 Pin Assignment
1 2 3 4 5 6 7 8
170068
Table 23
RJ-45 Signal Assignment by Pin
Pin
Signal
1
Line 1 tip
2
Line 1 ring
3
Line 2 tip
4
Line 0 tip
5
Line 0 ring
6
Line 2 ring
7
Line 3 tip
8
Line 3 ring