F I N A L D R A F T - C I S C O C O N F I D E N T I A L
9-62
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
9.7.46 SET-TH-ENV
Command
SET-TH-ENV
Sets threshold values of the environmental (power bus) parameters of the ONS 15216 EDFA2.
Syntax
SET-TH-ENV:[<tid>]:<aid>:<ctag>::<thresholdtype>,<thresholdvalue>[,,];
Example 9-49 SET-TH-ENV Command
Amp01:ONS15216 EDFA2> SET-TH-ENV:Amp01:PWR-A:100::PWRBUSMIN,450;
threshholdtype
and
thresholdvalue
pairs
string
Type of threshold that is to be set. The threshold is set to the
thresholdvalue that follows the comma. Possible to specify
values for one or more of the following:
LOSHYST
Loss of signal (input power) hysteresis
(cerent15216EdfaLOSHysteresis).
thresholdvalue can be between 0 and 1000, with default of
100, in units of 100 dB.
LOSTH
Loss of signal (input power) threshold
(cerent15216EdfaLOSThreshold).
thresholdvalue can be between –3100 and –1500, with
default of –3000, in units of 100 dBm.
LPOUTDEV
Loss of output power deviation
(cerent15216EdfaLpoutDeviation).
thresholdvalue can be between 0 and 1000, with default of
200, in units of 100 dB.
LPOUTHYST
Loss of output power hysteresis
(cerent15216EdfaLpoutHysteresis).
thresholdvalue can be between 0 and 1000, with default of
100, in units of 100 dB.
Table 9-52 SET-TH-DWDM Syntax Description (continued)
Parameter
Syntax
Description
Table 9-53 SET-TH-ENV Syntax Description
Parameter
Syntax
Description
aid
PWR-A, PWR-B, and ALL have same input effect.
PWR-A
Sets Power Bus A and Power Bus B.
PWR-B
Sets Power Bus A and Power Bus B.
ALL
Any or all of the preceding (command input only).