F I N A L D R A F T - C I S C O C O N F I D E N T I A L
9-58
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
Example 9-44 RTRV-TH-EQPT Command and Response
Amp01:ONS15216 EDFA2> RTRV-TH-EQPT:Amp01:ALL:123::MAXCTMP;
Amp01 2001-06-08 09:00:05
M 123 COMPLD
"EQPT:MAXCTMP,,,60"
;
Table 9-48 RTRV-TH-EQPT Syntax Description
Parameter
Syntax
Description
date
yyyy-mm-dd
Date of origination of TL1 message.
time
hh:mm:ss
Time of origination of TL1 message.
aid
EQPT and ALL have same input effect.
EQPT
General parameters of the ONS 15216 EDFA2 (not directly
affecting optical signal or power bus).
ALL
Any or all of the preceding (command input only).
threshholdtype
and
thresholdvalue
pairs
Type of threshold or set point that is to be retrieved. A null
value is equivalent to ALL. Possible to specify values for one
or more of the following:
MAXCTMP
Maximum case temperature (cerent15216EdfaCtmpMax).
thresholdvalue can be between 20 and 70, with default of 65 in
units of
°
C.
MAXCTMPHYST
Maximum case temperature hysteresis
(cerent15216EdfaCtmpMaxHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°
C.
MINCTMP
Minimum case temperature (cerent15216EdfaCtmpMin).
thresholdvalue can be between –10 and 10, with default of –5,
in units of
°
C.
MINCTMPHYST
Minimum case temperature hysteresis
(cerent15216EdfaCtmpMinHysteresis).
thresholdvalue can be between 0 and 10, with default of 1, in
units of
°
C.