F I N A L D R A F T - C I S C O C O N F I D E N T I A L
9-3
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
Summary of Autonomous Alarms and Messages
9.5 Summary of Autonomous Alarms and Messages
Table 9-4
summarizes the ONS 15216 EDFA2 autonomous alarms.
Table 9-3
TL1 Notation Symbols
Symbol
Meaning
Description
[ ]
Optional expression
Square brackets indicate the parameters are optional. An
optional parameter means that if a user inputs an empty
field for an optional parameter, then a default value (or a
default action) will be substituted automatically in the
transmitted input field. The default value, or null value,
is defined in the parameter descriptions of the messages.
< >
Variable expression
Angle brackets enclose one or more variable items in the
command line, e.g., <date>, <time>, <aid>, etc.
Italics are used to note variables in paragraph text, e.g.,
date, time, aid, etc.
+
More than one time
Plus signs indicate that preceding symbol or group of
symbols (enclosed in parentheses) may occur one or
more times.
text
Indent of three spaces
An indented line indicates an entry of three spaces in the
command line.
Table 9-4
TL1 Autonomous Alarms
TL1 Autonomous
Message
Condition
Type
(condtype)
Condition Descriptor
(conddescr)
Access
Identifier
(aid)
Notification
Code
(ntfcncde)
Service
Effect
(srveff)
REPT ALM DWDM
1
LOS
Loss Of Signal (input power) 1
MJ
SA
REPT ALM DWDM
1
GAIN
Gain Out Of Range
1
MJ
SA
REPT ALM DWDM
1
LPOUT
Loss Of Output Power
1
MJ
SA
REPT ALM ENV
PWRBUSA Power Bus A (voltage)
Alarm
PWR-A
MN/CR
2
–
REPT ALM ENV
PWRBUSB
Power Bus B (voltage)
Alarm
PWR-B
MN/CR
2
–
REPT ALM EQPT
CTMP
Case Temperature Out Of
Range
EQPT
MN
NSA
REPT ALM EQPT
LCRNT1
Excessive Pump1 Current
EQPT
MN
NSA
REPT ALM EQPT
LCRNT2
Excessive Pump2 Current
EQPT
MN
NSA
REPT ALM EQPT
LTMP1
Excessive Pump1
Temperature
EQPT
MN
NSA
REPT ALM EQPT
LTMP2
Excessive Pump2
Temperature
EQPT
MN
NSA