Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
8
Provisioning Using TL1
This chapter discusses the provisioning procedures for the Cisco ONS 15216 EDFA2 using TL1
commands in the TL1 shell. See
Chapter 4, “Provisioning Using ASH and SNMP”
for provisioning
information using command-line SNMP and proprietary commands in the ASH shell.
The provisioning procedure for the ONS 15216 EDFA2 in the TL1 shell is as follows:
1.
Log In via RS-232 (EIA/TIA-232) Port Using HyperTerminal, page 8-1
2.
Set IP Address, page 8-3
3.
Log In via LAN Port Using Telnet (Optional), page 8-3
4.
Set Date and Time, page 8-4
5.
Set Power Bus Mode (Simplex or Duplex), page 8-4
6.
Verify Amplifier Operational Status, page 8-4
7.
Set Gain, page 8-5
8.
Set Alarm Thresholds, page 8-5
9.
Set Password, page 8-10
10.
Add Users, page 8-11
11.
Log Off, page 8-11
12.
Back Up System Configuration, page 8-11
13.
Restore System Configuration, page 8-12
The following sections describe these steps in detail.
8.1 Log In via RS-232 (EIA/TIA-232) Port Using HyperTerminal
Logging in through the RS-232 (EIA/TIA-232) port is required to set the ONS 15216 EDFA2 IP address
before there can be access via the LAN port (see
“Log In via LAN Port Using Telnet (Optional)” section
on page 8-3
).
Step 1
Connect to the RS-232 (EIA/TIA-232) port on the ONS 15216 EDFA2. See
“LAN Connection
Procedure” section on page 3-15
for line connection and HyperTerminal setup instructions.
Step 2
Open HyperTerminal. (HyperTerminal can be found in the Microsoft Windows Accessories menu.)
Step 3
If you see the login window shown in
Example 8-1 on page 8-2
, skip to
Step 4
.