F I N A L D R A F T - C I S C O C O N F I D E N T I A L
9-49
Cisco ONS 15216 EDFA2 Operations Guide
78-16033-01
Chapter 9 TL1 Commands
TL1 Commands and Autonomous Messages
Table 9-40 RTRV-DWDM Syntax Description
Parameter
Syntax
Description
date
yyyy-mm-dd
Date of origination of TL1 message.
time
hh:mm:ss
Time of origination of TL1 message.
aid
1 and ALL have same input effect.
1
Directly affecting the optical signal.
ALL
Any or all of the preceding (command input only).
inputpoweruw
0 - 99999
Input power (signal) in units of 10 microW
(cerent15216EdfaInPoweruW).
inputpowerdbm
–999999 -
999999
Input power (signal) in units of 100 dBm
(cerent15216EdfaInPowerdBm).
outputpowermw
0 - 999999
Output power in units of 100 mW
(cerent15216EdfaOutPowermW).
outputpowerdbm
–99999 - 99999
Output power in units of 100 dBm
(cerent15216EdfaOutPowerdBm).
pump1ctrlmode,
pump2ctrlmode
Pump 1 or pump 2 control mode (maps to
cerent15216EdfaPumpCfgControlMode for the corresponding
pump). Possible values are:
GAINTEMP
Constant Gain Temperature Compensated mode (manufacturer
default) (cerent15216EdfaPumpCfgControlMode set to
constGainTempComp).
OPWR
Constant Output Power mode
(cerent15216EdfaPumpCfgControlMode set to
constOutputPower). A valid mode only for pump 2.
CRNT
Constant Pump Current mode
(cerent15216EdfaPumpCfgControlMode set to constCurrent).
PWR
Constant Pump Power mode
(cerent15216EdfaPumpCfgControlMode set to constPower).
IDLE
Pump is shut down (cerent15216EdfaPumpCfgControlMode
set to idle).
pump1ctrlvalue,
pump2ctrlvalue
Pump 1 or pump 2 control value. This value’s interpretation
depends on the control mode of the corresponding pump.
Possible values are:
0 - 650
Output power in units of 10 mW when mode is OPWR (gets
cerent15216EdfaPumpCfgConstOutPower).
0 - 300
Current value in mA when mode is CRNT (gets
cerent15216EdfaPumpCfgConstPumpCurrent).
0 - 100
Pump power in mW when mode is PWR (gets
cerent15216EdfaPumpCfgConstPumpPower).
gainmeasured
0 - 230
Value of gain in units of 10 dB when mode is GAINTEMP (gets
cerent15216EdfaConstGainOverallGainMeasured).