Table 58 (Continuation):
Modbus memory map: Configuration variables (Energy cost)
Energy cost
Configuration variable
Address
Valid data window
Default value
Cost per kWh of tariff 3 generation
27E2-27E3
0
to
100
(47)
0
Currency
27E4-27E7
7 ascii characters
EURO
(47)
The number of decimals are indicated at address
0x1586
. Format of the units: Power of 10 (with sign).
Note:
The 16 registers must be written and read at once (as a group), otherwise it will respond
with an error.
6�3�10�12�- CO
2
consumption and generation emissions
These parameters occupy 2 registers each.
Table 59:
Modbus memory map: Configuration variables (CO
2
emissions)
C0
2
emissions
Configuration variable
Address
Valid data window
Default value
Tariff 1 consumption emissions ratio
2774-2775
0
to
100
(48)
0
Tariff 2 consumption emissions ratio
2776-2777
0
to
100
(48)
0
Tariff 3 consumption emissions ratio
2778-2779
0
to
100
(48)
0
Tariff 1 generation emissions ratio
277A-277B
0
to
100
(48)
0
Tariff 2 generation emissions ratio
277C-277D
0
to
100
(48)
0
Tariff 3 generation emissions ratio
277E-277F
0
to
100
(48)
0
(48)
The number of decimals are indicated at address
0x1585
. Format of the units: Power of 10 (with sign)
.
Note:
The 12 registers must be written at once (as a group), otherwise it will respond with an
error.
6�3�10�13�- Relay digital outputs
The
Maximum Value
and
Minimum Value
configuration variables occupy 2 registers each.
All other variables
occupy 1 register each.
Table 60:Modbus memory map: Relay digital outputs�
Configuration of the digital outputs of the relay
Configuration variable
Address
Valid data margin
Default value
Output 1
Output 2
Maximum value
(49)
4E48-4E49 4E5C-4E5D
0
Minimum value
(49)
4E4A-4E4B 4E5E-4E5F
0
Connection delay (ON)
4E4C
4E60
0
to
999
seconds
0
Disconnection delay (OFF)
4E4D
4E61
0
to
999
seconds
0
Pre-alarm value
4E4E
4E62
0
to
100
%
0
Output status
4E4F
4E63
0
: Normally open
1
: Normally closed
0
Interlocking (latch)
4E50
4E64
0
: Unlocked
1
: Locked
0
Not used
4E51
4E65
0
0
Variable code
4E52
4E66
0
Module no.
4E53
4E67
0
0
(49)
The decimal for the selected variable must be included when programming the maximum and minimum values.
246
CVM-A1000 - CVM-A1500
Instruction Manual
Summary of Contents for CVM-A1000
Page 2: ...2 CVM A1000 CVM A1500 Instruction Manual...
Page 364: ...13 CE CERTIFICATE 364 CVM A1000 CVM A1500 Instruction Manual...
Page 365: ...365 Instruction Manual CVM A1000 CVM A1500...
Page 366: ...366 CVM A1000 CVM A1500 Instruction Manual...