Raption 50 Series Service Manual
The ISOMETER isoEV423 monitors the insulation charging stations for electric
vehicles for DC between 0 and 1100Vdc.
This device protects both DC connectors in the output side. It is measuring constantly
the resistance between positive wire to the ground and negative wire to the ground.
If the resistance value is very low it will generate an alarm as it is needed a high
value to keep the safety.
G
Isolation protection device
Power ON LED: It will be in green if the device is power up. It will be flashing if
there is some connection error.
Alarm LED, “AL1”: Lights when alarm value AL1 has activated or overvoltage
alarm (flashes during connection error).
Alarm LED, “AL2”: Lights when alarm value AL2 has activated or undervoltage
alarm (flashes during connection error).
Alarm 2 advices that resistance value is getting closer to the limit value. It
notifies the Mode 4 board but does not stop the operation of the Charging Station.
It is just a warning
It is the Alarm 1 the one that stops Charging Station operation because there is
not enough resistance to ensure the isolation protection.
Operation LEDs
Summary of Contents for Raption 50 Gen2 Series
Page 1: ...Service Manual Raption 50 Gen2 Series ...
Page 2: ......
Page 4: ...0 ...
Page 7: ...03 8 Maintenance 80 9 Annexes 84 10 Technical data 86 11 Need help 90 ...
Page 12: ...08 Raption 50 Series Service Manual B Dimensions Units specified in millimeters ...
Page 14: ...10 Raption 50 Series Service Manual 1 ELECTRONIC BOARDS ETC UPPER PART ...
Page 16: ...12 Raption 50 Series Service Manual 2 POWER MODULES MEDIUM PART 1 7 2 3 4 6 5 13 8 9 12 11 10 ...
Page 21: ...17 6 BLOCK DIAGRAM ...
Page 23: ...19 Raption 50 Series Service Manual ...
Page 55: ...51 ...
Page 94: ...90 Raption 50 Series Instruction Manual 11 Raption 50 Series Service Manual ...