Maximum AC input current
76 A (38 A*)
108 A (70 A*)
108 A (70 A*)
138 A (101 A*)
Required power supply
capacity
53 kVA (26 kVA*)
75 kVA (48 kVA*)
75 kVA (48 kVA*)
96 kVA (70 kVA*)
Maximum output power
50 kW (25 kW*)
(@400 VDC)
DC:50 kW (25 kW*)
(@400 VDC)
AC:22 kW
DC:50 kW (25
kW*) (@400 VDC)
AC:22 kW
DC:50 kW (25 kW*)
(@400 VDC)
AC:43 kW
Output voltage range
DC:50 - 500 V
DC: 50 - 500 V
AC: 400 V
DC: 50 - 500 V
AC: 400 V
DC: 50 - 500 V
AC: 400 V
Maximum output current
DC:125 A
DC:125 A
AC:32 A
DC:125 A
AC:32 A
DC:125 A (63 A*)
AC:63 A
Connection
CCS 2 - JEVS
G105
CCS 2 - JEVS G105
Type 2 Socket
(Lock
system)
CCS 2 - JEVS
G105
Type 2 Tethered
cable
CCS 2 - JEVS G105
Type 2 Tethered
cable