81
Maintenance
The maintenance plan is based in years from start-up, hours of charging or standby,
and cycles of charging. Depending of the group of components, is necessary to
apply a specific maintenance period. Check the periods in the next table:
* Raption WearCheck list
** Should be replaced every time top hat is opened to assure IP
Key: I Inspection C Clean R Replace
Years from start-up
6 months /
2K cycles
1 year /
4K cycles
2 years /
8K cycles
3 years /
12K cycles
4 years /
16K cycles
5 years /
20K cycles
Estimated time (hours)
for replacement
General maintenance
Preventive maintenance*
I
I
I
I
I
I
1,5
Control devices
Screen ensemble Raption 50
-
I
I
I
I
R
0,3
Connectors and sockets
Type 2 Connector
-
I
I
R
I
I
0,75
CCS Connector
-
I
I
R
I
I
0,75
CHAdeMO Connector
-
I
I
R
I
I
0,75
Power
Power modules
-
I
I
I
I
R
0,25
SuperCapacitors Board
I
I
R
I
R
I
0,15
Contactors and relays
Switching contactors
-
-
I
-
I
R
0,5
Switching relays
-
-
I
-
I
R
0,15
Power contactors/relays
-
I
R
I
R
I
2
Ventilation and heating
Control part fans
-
I
I
R
I
I
1,5
Power part fans
-
I
I
I
I
R
1
Filters
-
R
R
R
R
R
1
Isolation top hat seal**
-
R
R
R
R
R
0,5
Summary of Contents for Raption 50 Gen2 Series
Page 1: ...Service Manual Raption 50 Gen2 Series ...
Page 2: ......
Page 4: ...0 ...
Page 7: ...03 8 Maintenance 80 9 Annexes 84 10 Technical data 86 11 Need help 90 ...
Page 12: ...08 Raption 50 Series Service Manual B Dimensions Units specified in millimeters ...
Page 14: ...10 Raption 50 Series Service Manual 1 ELECTRONIC BOARDS ETC UPPER PART ...
Page 16: ...12 Raption 50 Series Service Manual 2 POWER MODULES MEDIUM PART 1 7 2 3 4 6 5 13 8 9 12 11 10 ...
Page 21: ...17 6 BLOCK DIAGRAM ...
Page 23: ...19 Raption 50 Series Service Manual ...
Page 55: ...51 ...
Page 94: ...90 Raption 50 Series Instruction Manual 11 Raption 50 Series Service Manual ...