42
Raption 50 Series Installation Manual
Raption 50 Series Service Manual
The thermostat is configured at -15ºC. If temperature is lower than this value,
contactor will open.
When K13.3 contactor opens, it does two functions simltaneously:
1 — Disconnects the supply of the internal components.
2 — Activates the heater.
So, as a result, when the Charging Station is powered and the environmental
temperature is lower than -15ºC this system is activated. Even being powered,
the Charging Station will remain with all the components turned off while heater
is activated.
When temperature is high enough, Raption will start to work normally.