87
Technical Data
ELECTRICAL DATA
Power supply
3P+N+PE
Voltage range
400 VAC +/- 10%
Power factor
>
0.98
Efficiency
95 % at nominal output power
Standby consumption
38 W
THDi
< 5%
Frequency
50/60 Hz
Electrical protections
Overcurrent protection, RCD and Overvoltage protection *
AC electrical meter
EN 50470-1 and EN 50470-3 (MID European standards)
Overcurrent protection
MCB class C
Safety protection
RCD type A (type B optional)
CONNECTIVITY
Ethernet
10/100BaseTX (TCP-IP)
Cellular
Modem 4G / GPRS / GSM / WiFi Hotspot *
Interface protocol
OCPP 1.5 or OCPP 1.6J
ENVIRONMENTAL CONDITIONS
Operating temperature
-30ºC to +45ºC
Storage temperature
-40ºC to +60ºC
Operating humidity
5% to 95% Non-condensing
Sound level in operation
<
55 dB
(*)