30
ENGLISH
• Gasket destruction > Overrun of operating conditions (check
the operating parameters).
• Plate destruction > Corrosion or erosion (check the type and
speed of the fluids being circulated; install filters).
• Plate destruction > Overpressure (check the pressure of the
fluids; watch out for sudden or frequent changes in pres-
sure or temperature).
• Plate destruction > The heat exchanger has frozen (either
make sure that the room temperature does not drop below
0°C while the system is not in use or drain the circuits).
• Leaks > The tightening dimension is wrong (check the tight-
ness of the plate pack).
• Leaks > The frame or a number of plates are dented (con-
tact CIPRIANI).
• Pollution > Leak of a dangerous or polluting fluid (have spill
trays on hand).
• Explosion > Accidental mixing of circulating fluids resulting
in the release of explosive fumes (make sure that resulting
mixture is not dangerous).
Prohibit access to the system by unauthorised personnel.
Make sure that servicing technicians
have the proper training.
Keep this manual near the heat exchanger.
1.5 - Receiving the unit
• Upon delivery, check the contents for missing or damaged
items. Note any missing or damaged items on the delivery
slip. Inform the CIPRIANI of said damaged or missing items
by registered letter within three days of delivery and forward
a copy to CIPRIANI.
• The front of each heat exchanger is fitted with a nameplate
listing a serial number. Please state this number in all cor-
respondence.
1.6 - Handling
• The handling and unloading equipment is for the account of
the recipient.
• Follow the rigging instructions (Figures 1a, 1b and 2).
• Use web slings (no metal chains). Insert them in the desig-
nated notches on the head and follower.
• The unit’s weight is stated on the delivery slip and the ship-
ping note.
• When moving and handling the heat exchanger, make sure
that it is properly supported and secured as its high centre
of gravity may cause it to tip over easily.
• Never lift the unit by its guide rails, compression bolts or
pipes, as doing so can cause them to bend.
• Shield the plates from impacts as they could cause irrepara-
ble leaks.
Summary of Contents for S020+
Page 124: ...124 1 2 60 C CIPRIANI CIPRIANI PED 2014 68 PED 2014 68 CIPRIANI...
Page 125: ...125 RU CIPRIANI...
Page 126: ...126 0 C CIPRIANI CIPRIANI 1 1b 2...
Page 127: ...127 RU 1a 1b 2...
Page 128: ...128 1 2 3 4 5 6 7 8 9 10 11 12...
Page 129: ...129 RU TS PS PT PED 2014 68 CE PED 2014 68 I II III IV CE II III IV 1 2 d d...
Page 131: ...131 RU 60 C 0 C 60 C 500 5 7 4 2 4...
Page 132: ...132 TF PB...
Page 133: ...133 RU CIPRIANI 10...
Page 134: ...134 1 2 3 4 1 2 3 4 4 1 5 CIPRIANI 1 2 3 4 11 5 6 Plug In...
Page 136: ...136 1 2 40 C 3 4...
Page 138: ...138 CIPRIANI 6 Plug In 7 Plug In Plug In 8 Plug In 5 7 1 A 7 6...
Page 139: ...139 RU Plug In 9 b 5 7 3 Plug In Plug In 9 5 7 3 Plug In 5 7 1 Plug In DN200 2 3 5 2 ACS 8 9...
Page 140: ...140 10 11 CIPRIANI PS 10 Fig 10 Fig 11...
Page 144: ...144 CIPRIANI CIPRIANI...
Page 145: ...145 RU CIPRIANI NBR EPDM FPM HNBR...
Page 146: ...146 Note...
Page 147: ...147 Note...