
8W-66 POWER TOP
DESCRIPTION AND OPERATION
POWER TOP OPERATION W/POWER WINDOWS
This vehicle uses a unique power window system
that works with the operation of the power top sys-
tem. The windows will operate in the DOWN mode,
for a specified period of time, when the power top
switch is activated.
NOTE: Refer to section 8W-60 for circuit operation
of this system. For further information on system
operation, refer to group 8S-Power Windows in this
service manual.
POWER TOP
The power top system uses a switch, a hydraulic
pump motor, and two relays.
Power for the switch is supplied on circuit F20.
This circuit is HOT when the ignition switch is in the
RUN position and is protected by a 15 amp fuse
located in cavity 4 of the junction block.
Circuit A22 is connected between the ignition
switch and the fuse. Power for the A22 circuit is sup-
plied by circuit A2. This circuit originates in the
Power Distribution Center (PDC) and is protected by
a 40 amp fuse located in cavity 18.
Ground for the switch is supplied on circuit Z1.
This circuit terminates at the instrument panel left
side cowl.
The switch has a Light Emitting Diode (LED) for
night illumination. The LED is powered by the F20
circuit.
DOWN OPERATION
When the operator selects top DOWN, circuit F20
is connected to circuit P5. The P5 circuit connects
from the switch to the power top DOWN relay. Volt-
age flowing through the coil side of the relay causes
the contacts in the relay to CLOSE connecting cir-
cuits A25 and P4.
The A25 circuit is protected by a 40 amp fuse
located in cavity 11 of the PDC.
Circuit P4 connects from the relay to the pump
motor. Voltage flows through the motor to circuit P3.
The P3 circuit provides the ground path for the
motor back to the relay assembly. Internal to the
relay circuit P3 connects to circuit Z1. The Z1 ground
circuit terminates at the instrument panel left side
cowl.
UP OPERATION
When the operator selects top UP, circuit F20 is
connected to circuit P6. The P6 circuit connects from
the switch to the power top UP relay. Voltage flowing
through the coil side of the relay causes the contacts
in the relay to CLOSE connecting circuits A25 and
P3.
The A25 circuit is protected by a 40 amp fuse
located in cavity 11 of the PDC.
Circuit P3 connects from the relay to the pump
motor. Voltage flows through the motor to circuit P4.
The P4 circuit provides the ground path for the
motor back to the relay assembly. Internal to the
relay circuit P4 connects to circuit Z1. The Z1 ground
circuit terminates at the instrument panel left side
cowl.
HELPFUL INFORMATION
•
Check the 40 amp fuses located in cavities 11
and 18 of the PDC
•
Check the 15 amp fuse located in cavity 4 of the
junction block
•
Check for a good ground at the instrument panel
left side cowl
JX
8W - 66 POWER TOP
8W - 66 - 3
Summary of Contents for 1997 Stratus Convertible LHD
Page 22: ......
Page 186: ......
Page 224: ......
Page 234: ......
Page 237: ...Charging System Schematic Typical JX CHARGING SYSTEM 8C 3 DIAGNOSIS AND TESTING Continued ...
Page 246: ......
Page 320: ......
Page 326: ......
Page 333: ...Fig 9 Wiper Motor Test JX WINDSHIELD WIPERS AND WASHERS 8K 7 DIAGNOSIS AND TESTING Continued ...
Page 358: ......
Page 380: ......
Page 386: ......
Page 396: ......
Page 398: ......
Page 414: ......
Page 464: ......
Page 468: ......
Page 472: ......
Page 496: ......
Page 532: ......
Page 536: ......
Page 572: ......
Page 584: ......
Page 592: ......
Page 598: ......
Page 610: ......
Page 624: ......
Page 628: ......
Page 632: ......
Page 636: ......
Page 640: ......
Page 702: ......
Page 726: ......
Page 733: ...Fig 8 Body Splices JX 8W 95 SPLICE LOCATIONS 8W 95 7 DESCRIPTION AND OPERATION Continued ...
Page 734: ...Fig 9 Rear Body Splices 8W 95 8 8W 95 SPLICE LOCATIONS JX DESCRIPTION AND OPERATION Continued ...
Page 735: ...Fig 10 Door Splices JX 8W 95 SPLICE LOCATIONS 8W 95 9 DESCRIPTION AND OPERATION Continued ...
Page 736: ......
Page 913: ...Fuel Line Adapter 1 4 JX FUEL SYSTEM 14 59 SPECIAL TOOLS Continued ...
Page 914: ......
Page 1033: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC JX TRANSAXLE 21 65 SCHEMATICS AND DIAGRAMS Continued ...
Page 1034: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC 21 66 TRANSAXLE JX SCHEMATICS AND DIAGRAMS Continued ...
Page 1035: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC JX TRANSAXLE 21 67 SCHEMATICS AND DIAGRAMS Continued ...
Page 1036: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC 21 68 TRANSAXLE JX SCHEMATICS AND DIAGRAMS Continued ...
Page 1037: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC JX TRANSAXLE 21 69 SCHEMATICS AND DIAGRAMS Continued ...
Page 1038: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC 21 70 TRANSAXLE JX SCHEMATICS AND DIAGRAMS Continued ...
Page 1039: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC JX TRANSAXLE 21 71 SCHEMATICS AND DIAGRAMS Continued ...
Page 1040: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC 21 72 TRANSAXLE JX SCHEMATICS AND DIAGRAMS Continued ...
Page 1041: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC JX TRANSAXLE 21 73 SCHEMATICS AND DIAGRAMS Continued ...
Page 1042: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC 21 74 TRANSAXLE JX SCHEMATICS AND DIAGRAMS Continued ...
Page 1043: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC JX TRANSAXLE 21 75 SCHEMATICS AND DIAGRAMS Continued ...
Page 1044: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC 21 76 TRANSAXLE JX SCHEMATICS AND DIAGRAMS Continued ...
Page 1045: ...41TE TRANSAXLE HYDRAULIC SCHEMATIC JX TRANSAXLE 21 77 SCHEMATICS AND DIAGRAMS Continued ...
Page 1054: ......
Page 1070: ......
Page 1166: ......
Page 1169: ...JX EMISSION CONTROL SYSTEMS 25 3 DESCRIPTION AND OPERATION Continued ...
Page 1196: ......