Power Supply Operation
3-25
2. Press the
Menu
button once to confirm. Rotate the knob to the VRANGE.
3. Press the
Menu
button once to confirm. A blinking VMAX will show on the display.
4. Press the
Menu
button once to confirm. You are allowed to set a maximum voltage value.
5. Press the
Menu
button once to confirm, and then set a minimum voltage value.
6. Press the
Menu
button once to confirm. The display will show the display status with the
minimum voltage you set.
3.11.6 Style
You can display the following condition after rebooting your power supply.
To show “OUTPUT OFF” on the display, you have to select 0 through the menu operation of
the path, Menu > SYSTEM >STYLE. To show “CV & CC Limit Setting with lit annunciators,
Limit and OFF” you have to select 1 through the menu operation of the path, Menu >
SYSTEM >STYLE. This setting doesn’t support Master/Slave mode, and SEQ mode.
Front Panel Operation:
1. Press the
Menu
button once. Rotate the knob to the SYSTEM.
2. Press the
Menu
button once to confirm. Rotate the knob to the STYLE.
3. Press the
Menu
button once to confirm. Rotate the knob to 0 for showing “OUTPUT OFF”
on the display after rebooting your power supply. Rotate the knob to 1 for showing “CV &
CC Limit Setting with lit annunciators, Limit and OFF” on the display after rebooting your
power supply.
4. Press the
Menu
button once to confirm.
3.11.7 Identification
You can read the identification string about the power supply via this menu. An identification
string about the power supply contains brand name, model name, serial number, main MCU
firmware version, and USB/GPIB card firmware version if the power supply has USB/GPIB
card built in.
The identification string can also query by the command *IDN?.
Front Panel Operation:
1. Press the
Menu
button once. Rotate the knob to the SYSTEM.
2. Press the
Menu
button once to confirm. Rotate the knob to the ABOUT.
3. Press the
Menu
button once to confirm.
4. The following message is an example. The identification string with a brand name, a
model name, a serial number, and a firmware version is scrolling on the display.
CHROMA ATE,62010L-36-7,L01000000066,1.00-1.00
Remote Operation:
*IDN?
Query the identification string of the power supply. The returned identification string is like
CHROMA ATE,62010L-36-7,L01000000066,1.00-1.00.