Appendix A: Serial API Commands
CP2210 User Manual
A-25
020-100410-07 Rev. 1 (01-2012)
STRT
Start motor moving in specified direction, where direction can be (-1, 1). Write-only for v1.3 or newer.
STOP
Stops the motor. Write-only for v1.3 or newer.
MOVR
Moves the motor a given number of steps based on the current location. Write-only for v1.3 or newer.
EXAMPLES:
(ZOM 500 1) Move lens to position 500 with positive approach
(ZOM 500 -1) Move lens to position -500 with negative approach
(ZOM+C101 -500 1) Set lens zoom position for channel 1 to -500 with positive approach.
(ZOM ?) Return current motor position
(ZOM + CALB 1) Calibrate the zoom
(ZOM + RSET 1) Reset the zoom
(ZOM+STRT 1) Starts motor moving in positive direction
(ZOM+STOP) Stops motor
(ZOM+MOVR -100) Move motor 100 steps in negative direction
(ZOM+MOVR 200) Move motor 200 steps in positive direction.
Summary of Contents for Solaria CP2210