![background image](http://html.mh-extra.com/html/christie/solaria-cp2210/solaria-cp2210_user-manual_2604063114.webp)
7-4
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)
Section 7: Maintenance
7.7
Inspect and Clean Lamp Blower
NOTICE! DO NOT bend the impeller blades or loosen the balancing weights.
A clogged lamp blower impeller or motor can reduce air flow leading to possible overheating and lamp failure
of the lamp.
1. Vacuum loose dirt from the lamp blower impeller.
2. If necessary, use a brush with hot water.
7.8
Replace the Lamp
1)Lamp replacement must be performed by a qualified service technician. 2)
EXPLOSION HAZARD. Wear authorized protective clothing whenever the lamp door is open and when
handling the lamp. Never twist or bend the quartz lamp body. Use the correct wattage lamp supplied by
Christie. 3) Ensure those within the vicinity of the projector are also wearing protective safety clothing.
4) Never attempt to remove the lamp when it is hot. The lamp is under pressure when hot and may
explode, causing personal injury, death, or property damage. Allow the lamp to cool completely before
replacing it.
Improper installation of the lamp can damage the projector.
1. Tap and hold the red power button
on the TPC
Main
panel to turn the lamp and projector off.
2. Allow the lamp to cool for a minimum of 10 minutes.
3. Unplug the projector.
4. Put on your protective clothing and face shield.
5. Unlock and open the lamp door. Release the tethered latch mechanism to remove the door entirely.
6. Remove the old lamp and inspect the reflector:
a. Remove the 2 captive screws securing the isolator (
Figure 7-2/C
).
a. Remove the screw securing the anode wire with a 5mm hex key. (
Figure 7-2/D
).
b. Loosen the cathode screw (
Figure 7-2/E
) on the rear access nut (
Figure 7-2/F
).
c. Hold the lamp from the anode end and carefully unscrew and remove the cathode nut (
Figure 7-2/F
).
d. Hold the lamp from the anode end and carefully slide out ensuring not to make contact with the
reflector.
e. With your free hand guide the cathode end out of the reflector, on an angle.
f. Before placing the old lamp into the protective case ensure the cathode nut is reinstalled. Place the
lamp, within the case, on the floor where it cannot fall or be bumped.
WARNING!
Handle box
with extreme caution - the lamp is hazardous even when packaged. Dispose of lamp
box according to local area safety regulations.
DANGER
WARNING
Summary of Contents for Solaria CP2210
Page 1: ...CP2210 U s e r M a n u a l 020 100410 07 ...
Page 2: ......
Page 3: ...CP2210 U S E R M A N U A L 020 100410 07 ...
Page 10: ......
Page 14: ......
Page 26: ......
Page 32: ......
Page 48: ......
Page 110: ......
Page 120: ......
Page 126: ......
Page 152: ......