![background image](http://html.mh-extra.com/html/christie/solaria-cp2210/solaria-cp2210_user-manual_2604063122.webp)
8-2
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)
Section 8: Troubleshooting
8.3
Lamp Suddenly Turns Off
• Tap
Menu
>
Advanced Setup
>
Lamp Power/LiteLOC Setup
. Increase the lamp power.
• Tap
Menu
>
Status
and then
Interlocks
in the left pane. Review and correct all interlock failures.
• If EVB errors occur, check the door interlock.
• Tap
Menu
>
Status
and then
Temperatures
in the left pane. Verify if the DMD temperatures are too high. If
the temperatures are too high, cool the projector. Ensure the projector is properly ventilated, the air filters are
not blocked, and the liquid cooling reservoir has coolant.
• Replace the lamp.
8.4
Flicker, Shadows, or Dimness
• Ensure the douser is open.
• Run a LampLOC™ adjustment.
• Verify that a LampLOC™ adjustment is not in progress.
• Tap
Menu
>
Advanced
Setup
>
LampPower/LiteLOC™ Setup
. Monitor the Power % field to determine
if the power is consistent or varying. Increase the lamp power. Lamps which are near end of service may not
operate reliably at a lower power setting.
• Fold mirror misalignment. Contact your Christie accredited service technician to resolve the issue.
• Integrator rod misalignment. Contact your Christie accredited service technician to resolve the issue.
8.5
LampLOC™ Not Working
• If the Do Auto option is not working, tap
Menu
>
Advanced
Setup
>
LampLOC™ Setup
and adjust the
lamp position manually. Observe screen brightness by adjusting the XYZ values or use a light meter to check
for changes in brightness.
8.6
LiteLOC
™
Not Working
• Tap
Menu
>
Advanced
Setup
>
LampPower/LiteLOC™ Setup.
Tap
Enable LiteLOC
™
.
• If the lamp power is at the maximum setting to maintain a LiteLOC™ setting, LiteLOC™ is automatically
disabled. Reduce the LiteLOC™ setting, or install a new lamp.
8.7
TPC
• If the TPC fails to initialize, restart the projector.
• If the TPC display is blank, ensure the TPC is on by opening the flap at the back of the TPC and verify the
grey button in the bottom left corner is ON.
• If the locations of button presses on the screen are misinterpreted, the TPC screen may need recalibrating.
Tap
Menu
>
Administrator Setup > Preferences
. Tap
Calibrate Screen
and follow the onscreen instruc-
tions.
Summary of Contents for Solaria CP2210
Page 1: ...CP2210 U s e r M a n u a l 020 100410 07 ...
Page 2: ......
Page 3: ...CP2210 U S E R M A N U A L 020 100410 07 ...
Page 10: ......
Page 14: ......
Page 26: ......
Page 32: ......
Page 48: ......
Page 110: ......
Page 120: ......
Page 126: ......
Page 152: ......