![background image](http://html.mh-extra.com/html/christie/solaria-cp2210/solaria-cp2210_user-manual_2604063146.webp)
A-20
CP2210 User Manual
020-100410-07 Rev. 1 (01-2012)
Appendix A: Serial API Commands
System Status (SST)
R
etrieve the various system status groups.
SUBCODE
DESCRIPTION OF USE
ALRM
Returns a summary of any active alarms
CONF
Returns configuration data - model, sn, build date, etc
COOL
Returns cooling data - cooling fans, air flow, etc
HLTH
Returns system health
INTE
Returns interlock data
LAMP
Returns lamp operational data.
NONE
Returns information on all status groups, with one message per item.
PERI
Returns peripherals data - Cine-IPM, etc
SECU
Returns security data
SERI
Return serial numbers
SIGN
Returns signal data - freq, etc.
SYST
Returns system data - power, hours of use, shutter open, etc
TEMP
Returns temperature data
VERS
Returns version numbers
EXAMPLE:
(SST+ALRM?) returns (SST+ALRM!000 002 “101” “Prism temperature”) where parameters are:
P1=index number,
P2=error level,
P3=value,
P4=description.
Error level is:
0=no errors or warnings,
1=warning,
2=error,
3=error and warning
Stop DLP Communication (STP)
Stop communications to DLP
®
Cinema Electronics temporarily, i.e. for DLP software upgrading.
SUBCODE
DESCRIPTION OF USE
NONE
0 - restart DLP communications;
1 - stop DLP communications.
EXAMPLES:
(STP 0) Restart DLP communication
(STP 1) Stop DLP communication
(STP?) Request current state. Example response is (STP!000)
Summary of Contents for Solaria CP2210
Page 1: ...CP2210 U s e r M a n u a l 020 100410 07 ...
Page 2: ......
Page 3: ...CP2210 U S E R M A N U A L 020 100410 07 ...
Page 10: ......
Page 14: ......
Page 26: ......
Page 32: ......
Page 48: ......
Page 110: ......
Page 120: ......
Page 126: ......
Page 152: ......