2-16
D4K35 Setup Guide
020-100855-02 Rev. 1 (09-2014)
Section 2: Installation and Setup
Table 2.2 Lamp Types Available for D4K35 and Anode Yoke Position
7. Install the lamp. See
Section 6.9 Replace the Lamp
for lamp replacement instructions.
2.15 Connect Lamp Power Supply (LPS)
When connecting the LPS and the Igniter the black (-) power cable must be
connected to the cathode lead and the red (+) power cable must be connected to the anode
lead. Reversing the connections can damage the projector.
You must connect the LPS to the projector before you connect it to AC power.
1) Certified electrician required. 2) Ground (earth) connection is necessary for
safety. Never compromise safety by returning the current through the ground. 3) Connect
ground FIRST to reduce shock hazard.
Use an appropriate strain relief connector on the AC supply cable to prevent
the cable from rubbing against the LPS knockout plate and becoming damaged
LAMP
TYPE
ANODE YOKE POSITION
2.0 kW and 3.0kW
CDXL-20
CDXL-30
CXL-20*
CXL-30
Move the lamp cradle to the rear position, which is approximately
1” closer to the reflector.
*
NOTE
: A lamp adapter kit must be used with the CXL-20 lamp.
4.5 and 6.0kW
CDXL-45
CDXL-60
Move the lamp cradle as far forward as possible (position closest
to igniter)
Figure 2-21 Anode Clamp Location
WARNING
WARNING
WARNING