Page 1: ...EmberCeptor AV Automatic Power Down ECEU US AV ENERGY EFFICIENCY TECHNOLOGIES User Manual ...

Page 2: ...ase retain your User Manual for future use In the event that you need some assistance with your EmberCeptor please email us at emberceptor embertec com Alternatively visit us on our website at embertec com emberceptor ...

Page 3: ...at is EmberCeptor AV p8 What Audio Visual Equipment p9 Can Be Connected To Your EmberCeptor AV Using your EmberCeptor AV p10 Using your EmberSensor p14 Active Power Down p16 Care and Maintenance p17 Troubleshooting Guide p18 Disposal Recycling p20 Warranty Details p23 m tor ...

Page 4: ... liquid This EmberCeptor AV is intended for household and commercial use only not for industrial use Disconnect from the power point before cleaning and when the EmberCeptor AV is not in use Do not plug this EmberCeptor AV into another device Do not insert needles or any other metal objects into the device outlets Avoid moisture extreme temperatures shock and vibration This device does not convert...

Page 5: ...should be supervised to ensure that they do not play with the EmberCeptor AV It is recommended to regularly inspect the EmberCeptor AV To avoid a hazard do not use the EmberCeptor AV if it becomes damaged in any way This EmberCeptor AV is for household and commercial use only not for industrial use Do not use this EmberCeptor AV for anything other than its intended use Do not use in moving vehicle...

Page 6: ...6 3 Your EmberCeptor AV EmberCeptor AV 1 Monitoring light 2 EmberSensor 3 Not Shown Overload protection circuit breaker re set button 1 2 ...

Page 7: ...button Not shown German and European general purpose outlets Infrared EmberSensor activates the Power Saver socket monitors activity and is also used to set the timing if required Comes with a 3 metre cable LED light and integrated push button control Active power down switches equipment off that is on but not in active use after a default period of 1 hour or user set timer of 2 or 3 hours Specifi...

Page 8: ...werdown can also be easily set to 2 or 3 hours or deactivated What Power is Wasted Many of today s appliances for the home and office continue to use power even when the appliance is turned off Appliances that are left on unintentionally or are in sleep mode waste even more power Automatic Power Down EmberCeptor AV featuring automatic power down works on two levels 1 Automatically switches off equ...

Page 9: ...y players Amplifiers Lamps NOTE Certain home theatre projectors require a cool down period and should be connected to the Always On socket or a free wall socket NOTE Certain consoles which are programmed to tape television shows such as pay TV and PVR units should be connected to the Always On socket NOTE The EmberCeptor AV saves wasted power consumed by all the connected Audio Visual AV component...

Page 10: ...e appliance that needs to be connected any power board powerstrip trailing socket or surge board may be connected to this socket Using Your EmberCeptor AV Connect the supplied EmberSensor cable to the underside of the EmberCeptor AV Fig 1 Place the EmberSensor in a convenient location that is in line of sight Close to your television is the best position and within normal operation of your existin...

Page 11: ...11 Using Your EmberCeptor AV continued Amplifier Console Speakers Stereo TV Cable Consoles and Recorders IR Sensor POWER SAVER ALWAYS ON ...

Page 12: ...Your Audio Visual AV system is now ready to use normally NOTE Only audio visual equipment to be connected to the EmberCeptor AV LED Monitoring Light Status The LED light on the EmberCeptor AV is ON whenever power has been applied to the Power Saver socket and OFF when power has been removed Warning If the EmberSensor light flashes frequently it may indicate it has sensed unwanted infrared activity...

Page 13: ... your existing remote s to operate your television digital television receiver or other Audio Visual AV components in the normal way Turning the Audio Visual AV Components off After Connecting the EmberCeptor AV Simply turn your equipment off in the normal way Once the Audio Visual AV components have been switched off the EmberCeptor AV will remove power from the Power Saving socket after a delay ...

Page 14: ...t is switched on or is in standby mode Press and hold down the button on the EmberSensor firmly for at least 3 seconds then release The LED light on the EmberSensor will flash for a few seconds whilst it enters Setting Mode As soon as the LED light on the EmberSensor has stopped flashing immediately begin to set the active power down to 2 hours 3 hours or completely de activated not recommended by...

Page 15: ...n standby Where no user activity button presses have been detected after 3 seconds the Setting Mode will be cancelled and the EmberCeptor AV will return to normal operation with a default active power down timer of 1 hour When the EmberCeptor AV is removed from the wall socket or power is switched off at the wall socket the EmberCeptor AV will revert to its default active power down setting of 1 h...

Page 16: ...down is imminent Cancelling or Interrupting the Active Power Down Simply press any button on any of your existing remote control s interact with your Audio Visual AV system or press the button on the EmberSensor This will cancel the active power down and return the timer to its default setting of 1 2 or 3 hours according to the user selected time Overload Protection The EmberCeptor AV is fitted wi...

Page 17: ...rCeptor AV device first switch off and remove the device from the power point Then wipe the exterior with a soft damp cloth Never use an abrasive cleaner When not in use store the EmberCeptor AV preferably in its original box in a cool clean and dry location ...

Page 18: ...ocess by switching on the Audio Visual AV component again waiting 10 seconds and switching off again The EmberSensor has not detected the infrared activity from your remote control Ensure you are using an infrared remote control and not a radio frequency remote control This may be an indication of unwanted infrared activity in the area Please check the immediate area for infrared devices that mayb...

Page 19: ... cable is safely and securely connected to the underside of the EmberCeptor AV and Press the button on the top of the EmberSensor when plugged into the EmberCeptor AV with the EmberCeptor AV switched on If the LED does not flash whenever you press the button it may be evidence of a faulty EmberSensor or connection Unplug all the appliances connected into the EmberCeptor AV device and then unplug t...

Page 20: ...g centre for safe recycling or disposal http uk simsrecycling com contacts and locations european recycling centreswww recyclingnearyou com au NOTE EmberCeptor complies with WEEE and RoHS regulations that restrict the use of certain hazardous substances in Electrical and Electronic Equipment EEE and aim to reduce the amount of Waste EEE and improve recovery and recycling rates ...

Page 21: ...21 Notes ...

Page 22: ...22 Notes ...

Page 23: ...Replacement Warranty does not apply to any defect deterioration loss injury or damage occasioned by or as a result of misuse or abuse negligent handling or if the product has been used other than in accordance with the instructions Embertec 12 Month Replacement Warranty The Embertec Replacement Warranty excludes breakables such as glass and ceramic items consumable items and normal wear and tear T...

Page 24: ...__________________ Attach a copy of the purchase receipt here Please don t return purchase record until you are making a claim For further assistance please contact us on emberceptor embertec com Due to continual improvement in design or otherwise the product you purchase may differ slightly from the illustration in this book Issue B10 Embertec 229 Greenhill Road Dulwich SA 5065 Australia Website ...