Section 2: Installation and Setup
D4K35 Setup Guide
2-19
020-100855-02 Rev. 1 (09-2014)
5. Using the line cord provided with the LPS, connect one end into the power connector labeled “Projector
ONLY” and the other end into the plug on the projector’s front bezel
(Figure 2-23).
DO NOT access power for the projector directly from the building electri-
cal source.
WARNING!
If you choose to use the power connectors to power the D4K35 Projector and/or the
Extraction Unit, you must terminate the power connector terminal block correctly to allow 200VAC-
240VAC output. These connectors are controlled with the power connector breaker. For details, refer to
the Interconnect Drawing provided with your projector and to
Figure 2-22 Connect LPS
.
6. Turn LPS Breaker ON.
7. If you are using the extraction unit and projector power connectors, turn them on.
8. Connect AC from the site to the projector (plug located on front bezel, bottom-right corner).(
Figure 2-24
)
WARNING
Figure 2-23 LPS Connection
Connect to AC at site
Communication
cables
Lamp leads
to extractor
(optional)
Projector &
Extraction Unit Power
Connectors
to projector
Connect to AC at site with owner supplied line cord
200-240VAC (as indicated on licence label)
Connect to AC at site
Communication
cables
Lamp leads
Figure 2-24 Connection to AC