Connect Devices to the SCCI Port
The Simple Contact Closure Port (SCCI) port is a DB-9 (male) connector is located on the PIB3G input panel
and is used to control a limited set of projector functionality through contact closures. This table lists the
control functions available through the SCCI:
Table 3.1 SCCI Connector Pinouts
NOTE
: All SCCI inputs require a pulse input of 50ms to several seconds to operate reliably. Inputs are 5V
resistor current limited LED’s inside of optocouplers.
A “Health Output” on this connector is also provided for locations that require a projector Health Output. The
output is an open-collector circuit which only draws power when the projector is deemed to be “un-healthy”.
The primary use of the Projector Health Output is to ensure that patrons are not left in a dark location due to
projector fault. Therefore, any fault that results in the content playback stopping should cause this circuit to
draw power and indicate an un-healthy state. The projector is always considered to be “healthy” in Standby
Mode since there is no fear of projector fault causing an impact to patrons in this mode.
PIN
SIGNAL NAME
DIRECTION
DESCRIPTION
1
+5V Standby
Out
Current limited 5VDC supply
2
Lamp ON
In
Projector at
Power ON
mode, lamp is
ON
3
+5V Standby
Out
Current limited 5VDC supply
4
Lamp OFF
In
Projector at full power, lamp is OFF
5
+5V Standby
Out
Current limited 5VDC supply
6
Douser Closed
In
Close douser
7
Douser Open
In
Douser open
8
Health Output
Out
Open Collector Low when one of the
following interlocks is tripped or condi-
tions present:
• Lamp Door
• Lamp Blower
• Extractor
• Tamper
• Ballast Communication
The show will not be able to play.
Open Collector High when all inter-
locks relevant to CineLink and Lamp
are not tripped. The show is able to
play.
9
Ground
Out
Ground