Service setups
HS Series D13 Service Manual
25
020-000892-03 Rev. 1 (12-2019)
1. On the IR remote keypad, press
Menu
and select
Size & Position > Size Presets > Full
Size
.
2. Enter
Factory mode
.
See
3. Select
ADC Calibration > Help
.
After a few seconds, the ADC calibration status changes from
Doing
to
Done
.
Adjusting the ROD assembly
Avoid over-adjusting the ROD to prevent damage.
1. Remove the top cover.
2. To power on with the top cover removed, firmly hold the interlock switch on the left-side cover.
3. Project an image of 100 inch in a dark environment (< 2 Lux).
4. Enter
Service mode
.
See
5. Click
Test Pattern
,
select the
White Screen
test pattern.
2
Test signal
D13HD-HS: Analog 1920 x 1080 @60Hz
D13WU-HS: Analog 1920 x 1200 @60Hz
3
Test pattern
SMPTE BAR
4
Inspection items
Check if the ADC calibration status has changed from
Doing
to
Done
.
Warning!
If not avoided, the following could result in death or serious injury.
• Do not look into the projector lens when the laser is on. The bright light may result in permanent
eye damage.
• This projector has a built-in Class 4 laser module. Never attempt to operate the projector without
all covers properly installed, unless instructed to do so in this manual for service.
ID
Part name
Description
Summary of Contents for D13HD-HS
Page 1: ...HS Series D13WU HS D13HD HS Service Manual 020 000892 03...
Page 112: ......