45
Operation - Model UL130
Model UL130 - Operation
1. Close the dishwasher front door.
2. Push the dishwasher Power Switch UP to turn the power ON.
3. The power switch will illuminate and the machine will fill with water.
4. Wait until the wash temperature gauge indicates a minimum of 120ºF/49ºC.
RUN THE FIRST CYCLE WITH AN EMPTY DISH RACK TO HEAT
THE WASH TANK INTERIOR.
5. Load the dish rack into the machine. Wash one dish rack at a time.
6. Close the door, then press the START BUTTON for 1 second. The green in-cycle
light will illuminate and the wash cycle will begin. The total cycle is approximately
141 seconds.
7. Opening the door during a cycle will stop the dishwasher. If the door is open more
than 5 seconds the cycle will restart from the beginning, if open less than 5 seconds
the cycle
will resume where it left off when the dishwasher door is closed.
8. The final rinse cycle begins at the end of the wash cycle. The machine drains and
then refills with fresh water hot water. Check the rinse temperature gauge during
the final rinse. It must indicate a minimum of 120ºF/49ºC. The final rinse water is
retained for the next wash cycle.
9. When the green cycle light goes out, open the door and remove the rack of clean
wares.
Normal Wash Mode
Combination Wash and Final
Rinse Temperature Gauge
Prime
Push buttons
Cycle Light
Start
Push button
ON-OFF/DRAIN
Power Switch
PRIME
OFF/DRAIN
ON
POWER
START
RINSE AID
DETERGENT
SANITIZER
160
140
120
10
0
80
60
20
170
180
190
200
21
0
220
70
80
95
90
100
105
C
F
60
50
40
20
0
NSF
TE
M
P
ER
A
TU
RE
EXT. WASH
D E L I M E
Extended Wash
Delime Switch
and Light
! VERY IMPORTANT !
5.25% sodium hypochlorite (chlorine beach) must be used as a sanitizing agent to
provide a minimum concentration of 50 ppm in the final rinse for the USA and 100 ppm
in Ontario, Canada. The 50 ppm or 100 ppm concentration must be
checked using chlorine test strips to make sure that the concentration is maintained.
Summary of Contents for UH130 M4
Page 68: ...58 Timer Board Connection Diagram All Models ...
Page 74: ...64 Blank Page This Page Intentionally Left Blank ...
Page 104: ...94 Blank Page This Page Intentionally Left Blank ...
Page 106: ...96 Wash Pump Motor Assembly All Models 1 11 12 2 3 4 5 7 8 9 10 6 13 14 15 ...
Page 111: ...101 Blank Page This Page Intentionally Left Blank ...
Page 114: ...104 Fill Solenoid Valve UH130 UH130B UH330B UL130 1 2 3 4 9 5 6 7 8 ...
Page 134: ...124 Booster Assembly UH130B UH230B 1 1 2 2 3 4 1 6 5 7 8 9 10 11 12 13 4 15 14 ...
Page 144: ...134 Control Panel UH130 UH130B 1 2 3 6 7 10 8 8 9 9 11 10 4 5 5 ...
Page 146: ...136 Control Panel UH230 UH230B 1 2 3 3 2 6 5 7 5 10 8 8 9 9 11 10 4 ...
Page 148: ...138 Control Panel UH330B 1 2 2 3 6 5 7 5 10 8 8 9 9 11 10 4 ...
Page 150: ...140 Control Panel UL130 7 9 8 3 6 1 2 4 4 10 7 5 5 3 Thermometer probe located in wash tank ...
Page 152: ...142 Panels UH130 UH130B UH230 UH230B UL130 1 10 2 3 4 6 5 7 8 9 11 12 13 13 ...
Page 154: ...144 Panels UH330B 1 3 4 2 5 6 7 9 8 ...
Page 156: ...146 Door Assembly All Models 1 10 4 5 6 6 7 7 9 9 8 10 2 3 3 5 ...
Page 158: ...148 Dish Racks Line Strainer PRV 1 2 3 4 ...
Page 160: ...150 This Page Intentionally Left Blank Blank Page ...
Page 162: ...152 Electrical Schematic UL130 UL130 ...
Page 164: ...154 Electrical Schematic UH330B UH330B ...
Page 165: ...155 Timing Charts UH130 UH130B UH230 UH230B UL130 UH230 UH230B UH130 UH130B UL130 UL130 ...
Page 166: ...156 Timing Chart UH330B UH330B Timing Charts ...