CG Drives & Automation 01-5980-01r2
Technical data
157
13. Technical data
1) Normal duty: Start current = 3 x I
n_soft
, Start time = 15 s (Size 1) or 30 s (Size 2- 4), 10 starts/hour,
Heavy duty: Start current = 5 x I
n_soft
, Start time = 15 s (Size 1) or 30 s (Size 2- 4), 10 starts/hour.
2) Fuse data for Semi-conductor fuses, see Table 48.
3) H1=Height of enclosure, H2= Total height.
Table 42 Technical data for Emotron TSA52/69-016 to -030.
Emotron TSA Size 1 model:
TSA52/69-016
TSA52/69-022
TSA52/69-030
Duty
(1)
Normal
Heavy
Normal
Heavy
Normal
Heavy
Rated current I
n_soft
[A]
16
10
22
12
30
18
Motor size P
n_mot
400 V [kW] - TSA52-###
7.5
4
11
5.5
15
7.5
Motor size P
n_mot
460 V [hp] - TSA52-###
10
5
15
7.5
20
10
Motor size P
n_mot
525 V [kW] - TSA52-###
11
5.5
15
7.5
18.5
11
Motor size P
n_mot
575 V [hp] - TSA69-###
15
7.5
20
10
25
15
Motor size P
n_mot
690 V [kW] - TSA69-###
11
7.5
18.5
11
22
15
Recommended load fuses [A]
(2)
25
25
35
35
40
40
Total power loss for TSA unit at rated motor
power, in bypass mode [W]
16
15
17
15
19
16
Total average power loss for TSA unit if
10 starts/hour [W]
35
34
39
37
45
43
Dimensions H1/H2 x W x D [mm (in)]
(3)
246/340 x 126 x 188 (9.7/13.4 x 5 x 7.4)
Mounting position
Vertical
Weight [kg]
5.5
Busbar for cable connection [mm (in)]
15 x 2 (0.59 x 0.08), M6 connection.
Possible to use either Cu or Al cables.
Cooling system
Convection
Protection class
IP20
UL short circuit rating
5 kA
Table 43 Technical data for Emotron TSA52/69-036 to -056.
Emotron TSA Size 1 model:
TSA52/69-036
TSA52/69-042
TSA52/69-056
Duty
(1)
Normal
Heavy
Normal
Heavy
Normal
Heavy
Rated current I
n_soft
[A]
36
21
42
25
56
33
Motor size P
n_mot
400 V [kW] - TSA52-###
18.5
7.5
22
11
30
15
Motor size P
n_mot
460 V [hp] - TSA52-###
25
15
30
20
40
25
Motor size P
n_mot
525 V [kW] - TSA52-###
22
11
30
15
37
22
Motor size P
n_mot
575 V [hp] - TSA69-###
30
20
40
25
50
30
Motor size P
n_mot
690 V [kW] - TSA69-###
30
18.5
37
22
45
30
Recommended load fuses [A]
(2)
50
50
63
63
80
80
Total power loss for TSA unit at rated
motor power, in bypass mode [W]
20
17
21
18
25
19
Total average power loss for TSA unit if
10 starts/hour [W]
49
46
51
48
61
56
Dimensions H1/H2 x W x D [mm (in)]
(3)
246/340 x 126 x 188 (9.7/13.4 x 5 x 7.4)
Mounting position
Vertical
Weight [kg (lb)]
5.5 (12.1)
Busbar for cable connection [mm (in)]
15 x 2 (0.59 x 0.08), M6 connection.
Possible to use either Cu or Al cables.
Cooling system
Convection
Protection class
IP20
UL short circuit rating
5 kA
Summary of Contents for emotron TSA Series
Page 1: ...Emotron TSA Softstarter Instruction manual English Valid from Software version 1 27...
Page 2: ......
Page 4: ......
Page 6: ...2 CG Drives Automation 01 5980 01r2...
Page 12: ...8 Introduction CG Drives Automation 01 5980 01r2...
Page 18: ...14 Mounting CG Drives Automation 01 5980 01r2...
Page 42: ...38 Application guidelines CG Drives Automation 01 5980 01r2...
Page 46: ...42 Getting started CG Drives Automation 01 5980 01r2...
Page 70: ...66 Main features CG Drives Automation 01 5980 01r2...
Page 142: ...138 Functionality CG Drives Automation 01 5980 01r2...
Page 158: ...154 Troubleshooting Diagnoses and Maintenance CG Drives Automation 01 5980 01r2...
Page 160: ...156 Options CG Drives Automation 01 5980 01r2...
Page 168: ...164 Technical data CG Drives Automation 01 5980 01r2...
Page 202: ...CG Drives Automation 01 5980 01r2 198...
Page 203: ......