Menus:
1. System components
- selection of existing components in the system and output configuration
2. Solar collector
- parameter setting of selected solar collector fields
3. Tank –
parameter setting of selected tanks
4. Tank reheating
- parameter setting of selected conventional sources for the tank reheating
5. Recirculation
- recirculation parameter setting in case of its existence
6. Legionella protection
- parameter settings for the tank disinfection ie legionella protection
7. Energy measuring
- parameter setting connected with the solar fluid and the flow through the solar collectors
8. Manual test
- testing of the operation of every individual component connected with the controller
9. Save/Load
- saving/deleting/loading the controller settings and returning the controller to factory settings
10. Information
- Browsing the error history , software version and the records of the enterings into the installation menu
11. Internet supervision
- WiFi network parameter settings for the controller connection with the Internet
12. Reset counters
- the return of the energy and glycol counter to zero ( 0 )
40
8. INSTALLATION
By pressing the key 8. Installation you enter the menus designed for the solar system configuration. To enter the menu it
is needed to write the PIN (0000) (which cannot be changed), to prevent the entering into this menu accidently.
In the menu 8. Installation the individual system components are set (it is not intended for everyday use).
MENUS FOR THE SYSTEM CONFIGURATION
Technical instructions
Cm
-SOL
Installation
THE NUMBERS OF MENU AND MENU
S
ARE CHANGING ACCORDING
TO THE SELECTED CONFIGURATION
(here are shown only fix numbers
(which are always the same), and other changeable numbers are marked
with x, menu depth where the parameter is located).