![Centrometal Cm-SOL Technical Instructions Download Page 67](http://html1.mh-extra.com/html/centrometal/cm-sol/cm-sol_technical-instructions_2582745067.webp)
67
Technical instructions
Cm
-SOL
Pump working time
5
Factory settings
min./max.
1 / 1440 min
8.x.2.Pump working time
Setting the recirculation pump working time when recirculation is active.
NOTE:
Time must be set according the recirculation system.
Recommendation is to set the working time as short as possible to
minimize cooling down the tank.
15
Factory settings
min./max.
0 / 1440 min
8.x.3. Pump pause time
Setting the recirculation pump pause time when circulation is active.
NOTE:
Time must be set according the recirculation system.
Recommendation is to set the pause time as long as possible to
minimize cooling down the tank.
8.x.4. Schedule
In this menu are additional menus for set the recirculation schedule.
Schedule can be enabled/disabled or select one of the two tables with
set time intervals for enabled and disabled function.
8.x.4.1. Schedule
In this menu schedule can be enabled/disabled and selected one of two
tables according to which DHW recirculation will work.
NOTE:
In case recirculation is enabled and shedule is disabled,
recirculation will always work according set times, 24/7, ie. recirculation
pump will work when is not needed and will cool down DHW tank and
increase fuel comsumption of the conventional heating source.
Factory settings
Schedule
OFF
OFF/Table 1/Table 2
8.x.4.2. Table 1
In this menu 3 time intervals can be set (3 start (green fields) and 3 stop
(red fields)) for each day of the week in which recirculation pump will
work according the set work/pause times.
Factory setting: recirculation is enabled from 06:00 h to 22:00 h every
day of the week. From 22:00 h of the first day to the 06:00 next day
recirculation is disabled.
Factory settings
Table 1
06:00-22:00 mon/tue/wed/thu/fri/sat/sun
Pump pause time
Installation, recirculation
8.x.4.3. Table 2
In this menu 3 time intervals can be set (3 start (green fields) and 3 stop
(red fields)) for each day of the week in which recirculation pump will
work according the set work/pause times.
Factory setting: recirculation is enabled from 06:00 h to 22:00 h every
day of the week. From 22:00 h of the first day to the 06:00 next day
recirculation is disabled.
Factory settings
Table 2
06:00-22:00 mon/tue/wed/thu/fri/sat/sun
unit.
unit.
selection
selection
selection