Example:configuration 2 tanks
1.x.
Enabled tanks
In this menu, you can switch on/off the individual tank in operation of the
system.
SWITCH ON
-
the tank is included in the system.
SWITCH OFF
-
the tank is switched off from the system (no pump or
valve is used, nor does it heat up).
NOTE:
If all tanks are switched off on the control unit
,
a warning will
appear!
(solar collectors do not fill any of the tank fast boiling
in
the
collector).
Tank 1
Switch on
Factory settings
selection
ON/OFF
Tank 2
Tank 3
Tank 4
Switch on
Switch on
Switch on
ON/OFF
ON/OFF
ON/OFF
1.x.
Tank priority
Selection of the priority for solar tank filling. Tank 1 must always be the
first priority, the other tanks can rotate at the priority of the charge. The
priority of each
tank is indicated in the upper left corner of the tank (green
number
), below the row number of the tank (black number).
Example:configuration 3 tanks
2 tank
3 tank
4 tank
12
123
1234
12
123 / 132
1234/1243/1324/1342/1423/1432
1.x.
Priority test
If there are more than one tank in the configuration, the tank priority test
may be switch on to periodically examine whether the collector
temperature is high enough to refill the priority tank.
After the priority tank
is filled
(or [T MAX tank1] or [Tcoll <Ttank1 +
TDcoll-ready] solar heating is switched to the next tank by priority. By
switching to the Priority Option, the next priority tank by
priority
will be
filled for a certain time (set under Priority filling) and then tank filling will
be stopped for a specified time (set under Priority Stand by) to make
sure the collectors can begin filling the priority tank or continue filling the
same tank. If the increase in temp.
of
the collector in the set idle time is
greater than or equal to [3°C / min.] the idle time is extended as long as
the temperature rises, ie when the priority tank can be refilled. If the
increase in temp. the collector in the set idle time
is
less than [3°C / min]
,
continues filling the same tank.
By using the Test Priority option in the 1.
Tank, appears the menus
Filling priority
and
Stand by priority
.
Test priority
OFF
Factory settings
selection
OFF/ON
1.7.
Filling priority
Priority test -> Switch on
Continuous filling time of the next tank in order (non-priority tank).
Filling priority
15
min./max.
0 / 720
min
unit.
P
P
P
User menu, tank
19
Technical instructions
Cm
-SOL
Factory settings
selection
Factory settings