3.x.1. Manual test pump S1
By pressing the button START the output is turned on (in this case the
tank 1 pumps) and by pressing the key STOP the output is turned off (in
this case the tank 1 pump). With the button RETURN it returns the
previous screen.
When the Manual test is switched on, the marking of the Manual test (M)
function lights yellow.
1 solar flat collector field / vacuum tube collector
/ 1 DHW tank / 1 buffer tank / pumps / electric
heater / boiler 1 / mixing/reheating / flow meter /
return sensor / outer temperature sensor /
recirculation
Depending on the selected output, with the buttons START and STOP
the individual outputs are manualy switched on or off.
3.x. Internet supervision
If the CM – WiFi BOX is embedded, the controller automatically
recognizes the device and under the user and PIN the menu Internet
supervision appears.
In this menu it is possible to switch on/off the supervision or the
supervision and control via the WiFi network, enter the name of the WiFi
network and the password, make the time synchronization , select the
time zone and do the manual reset of the connection.
The user can adjust and commission the WiFi Box by him/herself.
3.x.1. Internet supervision
In this menu it is possible to switch on and off the Internet supervision
and to choose only Supervision (it is not possible to change the
parameters) or Supervision and control (possible to change the
parameters).
selection
Internet
supervision
Sup.+control. OFF/Supervision/Sup.+control
Example: configurated 2 tanks with PWM
pumps, 1 conventional source, 1 electric heater,
recirculation pump and mixing pump
3.x. Manual test
Depending on the configurated system components and its
output
s,
during the manual test it is possible to test all turned on
output
s.
NOTE:
Number and type of menu depends on the turned on exits in the
installation menu.
If there are PWM outputs, in manual tests you can set wanted speed of
each PWM output (factory on 100%).