Section 1 - Outdoor Furnace Installation
H
C
M
R
Hot Supply
Water-to-Water
Heat Exchanger
Bypass Line
Hot Supply from Pump
on Outdoor Furnace
Return to Outdoor Furnace
Thermostatic Valve
Thermostatic
Mixing Valve
This horizontal assembly
must not exceed a height
of 4 inches (10 cm) above top
of water heater.
Existing
Water
Heater
1"
Central
PEX
®
Optional Bypass
Valve
Heat
Exchanger
Plenum
Existing
Forced Air
Furnace
For illustration purposes only,
water heater styles may vary.
NOTE
A pump must be installed in the hot
supply line between the outdoor furnace
and thermostatic valve. Outdoor furnace
water temperature setpoint should be
set at 185˚F (85˚C) minimum.
NOTE
On multi-speed fans, cap and
tape off any extra wires.
NOTE
Installer must comply with all
applicable codes and regulations.
NOTE
This configuration allows
use of a 24-volt thermostat
on older forced-air units
with no control board.
NOTE: A certified electrician must
perform the electrical installation.
WATER-TO-AIR HEAT EXCHANGER
AND WATER HEATER SYSTEM
C
R
Y
G
FAN
TIME
PRG
M RUN
HO
LD
SY
STE
M
COOL
ON
AU
TO
OFF
HEA
T
110-V Line
Voltage
White
G
Transformer
© 2015 Central Boiler
Thermostat
p/n 588
White
White
Ground, Hot and
Neutral Wires
at Furnace
White
Neutral
For illustration purposes only.
R
Black
Black
Neutral
Red
Ground
Fan Relay
Fan
Switch or
Snap Disc
on Furnace
Black
Brown
Fan Speed Tap Wires
(Connect Prefered Speed Tap Wire)
C
G
R
W2
E/W1
Y1
(O/B)
Y2
L
24-Volt Thermostat
C is optional
with batteries
Fig. 20
Summary of Contents for e-Classic 1450 IR
Page 17: ...15 Section 1 Outdoor Furnace Installation...
Page 29: ...27 Section 1 Outdoor Furnace Installation Fig 30 Fig 31...
Page 30: ...28 Section 1 Outdoor Furnace Installation Fig 32 Fig 33...
Page 66: ...64 E CLASSIC 1450 WIRING DIAGRAM Section 6 General Information...
Page 67: ...65 Section 6 General Information E CLASSIC 1450 WIRING DIAGRAM OPTIONAL POWER IGNITION...
Page 69: ...67 NOTES...
Page 70: ...68 NOTES...
Page 71: ...69 NOTES...