HI-PE multi-zone --- Rev.
FI 050 GB 60K10 v2_1
26
Code
Meaning
Possible
values
Type
Notes
whilst bar BD1 lights up completely.
GD=7 similar to GD=1, but both LED bars are deactivated.
GD=8 similar to GD=2, but both LED bars are deactivated.
(8
%'
%'
7;
(8
%'
%'
7;
(8
%'
%'
7;
(8
%'
%'
7;
(8
%'
%'
7;
GD=1 GD=2 GD=3 GD=5 GD=7
BM
LED bar
operating mode
CONT
BLIN
C,R
CONT during normal operation, the top segment of the LED bar on the probe is
continuously lit.
BLIN
during normal operation, the top segment of the LED bar on the probe blinks.
ST
Stores a set of
parameters
selected by the
user
1-10
C
Each detector is equipped with 10 sets of parameters specifically designed for some of the
most common applications
The
ST
command, however, allows another 10 sets of parameters to be stored in memory.
These parameters
are set by the user:
in order to do so the operator simply programs the
apparatus for the required operational application and then activates the
ST
command,
assigning an identification number.
From that moment onwards the detector stores that programming set-up in memory and the
operator may retrieve it for use should the programming be modified for any reason.
Obviously, if a set of parameters is recorded under an identification number that is already
in use, the new program overwrites the previous one.
ATTENTION!
If a problem occurs in the programming memory, the "PROG" message will
appear and the operation will not be executed.
LD
Loading stored
parameters
1-10
C
See function ST.
IS
International
Security
Standard
see the
following
table
C,R
During normal operation the current Security Level is displayed by pressing the
or
keys (see the following table).
UP
Selects the
commands that
can be accessed
by the user
Y,N
C,S
The command codes will be displayed followed by an indication in brackets of the current
status: (Y) = activated, (N) = deactivated
Local programming
The status of each command is changed by pressing the
or
keys. If you do
not wish to change the state of the command you need only press
and the display
will scroll to show the following command. Press the
key to interrupt the selection
procedure
Remote programming
(see
below)
The state of each command is changed by entering the opposite value to the current one to
the right of the # character. If the user does not wish to change the command state, he/she
can simply press ENTER, and the cursor will move on to the following command. Press "."
to interrupt the selection procedure.
AU
Autoset
.
-
C
Selects the factory-set standard values of operating parameters controlled by some
commands.
These standard values make up an additional set of parameters to those numbered 1 to 10
which can be recalled with the LD function.
By executing the AU command the detector will be set to the most generally-used operating
parameters, or alternatively to those which is best suited to a particular type of application
specified by the user (for customised models).
The command only relates to some parameters.
This command requests confirmation.