Diagnosis
Message
Possible cause
Recommended action
RX ERR
fault in the receiving section
•
Check the choice of transmission channel
(function CH) if more than one metal detector is
installed (see related para. in “Installation”
section)
• replace the electronics unit
GATE
connecting cable damaged or
disconnected
damaged transducer
• check the connections between electronics unit
and antennae
• check that no nails or screws have been driven
into the transducers without prior consultation
with the technical department of CEIA.
• replace the connecting cable
• replace the transducer
PROG
loading of data via the LD or IS commands
from an unprogrammed memory cell
• Programme the memory cell (ST command) or
use a pre-programmed memory cell.
RS232
serial interface malfunction
• check the serial line connections
• check that serial transmission mode has been
selected correctly at both the detector and the
remote terminal (see Programming section)
• replace the electronics unit
BUSY
attempt to access programming in local
mode while a session is already underway
in remote mode, or vice-versa.
• Exit from programming phase
WAIT
Metal detector not operative
• Temporary adjustment phase following to the
modification of either the receiving or the
transmitting parameters (e.g.: channel "CH"): wait
for normal functioning indication.
RESTART
Metal detector not operative
•
Temporary adjustment phase following to the exit
from the EN function.