![Carrier WEATHERMASTER 48Z030 Operation And Service Manual Download Page 14](http://html.mh-extra.com/html/carrier/weathermaster-48z030/weathermaster-48z030_operation-and-service-manual_2560339014.webp)
14
Table 9 — Fan Performance — 48ZG,ZN070 and 50ZG,ZN070 Units Without Discharge Plenum*
LEGEND
*If calculating static pressure for a 48 Series unit, be sure to add gas
heat pressure drop from Table 30B on page 32.
NOTES:
1. Fan performance is based on wet coils and clean 2-in. filters.
2. See Table 30B before using Fan Performance tables.
3. Conversion — Bhp to kW:
See Tables 26-28 for motor efficiency.
AIRFLOW
(Cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
14,000
258
2.23
297
2.80
330
3.38
362
4.02
392
4.73
422
5.53
451
6.42
480
7.37
17,500
302
3.92
338
4.67
368
5.39
395
6.10
421
6.84
446
7.64
471
8.50
495
9.42
21,000
348
6.36
380
7.29
408
8.18
434
9.04
457
9.88
479
10.74
501
11.64
522
12.57
24,500
397
9.74
424
10.80
450
11.88
475
12.91
497
13.91
517
14.89
537
15.88
556
16.89
28,000
447
14.18
470
15.35
494
16.60
516
17.82
538
19.01
558
20.16
576
21.29
594
22.41
30,000
476
17.29
497
18.50
519
19.82
541
21.15
562
22.45
581
23.70
599
24.93
617
26.14
AIRFLOW
(Cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
1.8
2.0
2.2
2.4
2.6
2.8
3.0
3.2
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
14,000
507
8.39
533
9.46
558
10.57
582
11.71
605
12.89
627
14.08
648
15.29
668
16.52
17,500
519
10.42
542
11.48
565
12.60
588
13.78
610
15.02
632
16.30
653
17.62
674
18.99
21,000
543
13.56
563
14.60
583
15.69
603
16.84
623
18.05
643
19.31
662
20.63
682
21.99
24,500
575
17.93
593
18.99
611
20.10
629
21.24
646
22.43
664
23.67
681
24.96
698
26.29
28,000
612
23.55
628
24.69
645
25.86
661
27.05
677
28.27
692
29.53
708
30.82
723
32.15
30,000
634
27.34
650
28.56
666
29.78
681
31.02
696
32.28
711
33.56
726
34.88
—
—
AIRFLOW
(Cfm)
AVAILABLE EXTERNAL STATIC PRESSURE (in. wg)
3.4
3.6
3.8
4.0
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
Rpm
Bhp
14,000
687
17.76
706
19.01
724
20.27
741
21.54
17,500
694
20.38
713
21.79
732
23.24
—
—
21,000
701
23.41
719
24.87
738
26.38
—
—
24,500
715
27.67
732
29.10
749
30.58
—
—
28,000
739
33.51
—
—
—
—
—
—
30,000
—
—
—
—
—
—
—
—
48/50ZN units only.
Bhp —
Brake Horsepower
Kilowatts =
Bhp x .746
Motor efficiency
Summary of Contents for WEATHERMASTER 48Z030
Page 103: ...103 Fig 15 Typical Power Schematic Sizes 030 050 Shown a48 8408 ...
Page 104: ...104 Fig 16 Main Base Board Input Output Connections a48 8409 ...
Page 105: ...105 Fig 17 RCB ECB CEM SCB Input Output Connections a48 8410 ...
Page 106: ...106 Fig 18 Typical Gas Heat Unit Control Wiring 48Z055 105 Units Shown a48 8411 ...
Page 107: ...107 Fig 19 Typical Electric Heat Unit Control Wiring 50Z055 105 Units Shown a50 8248 ...
Page 108: ...108 Fig 20 Typical Power Wiring 115 V 48Z Units a48 8412 ...
Page 109: ...109 Fig 21 Typical Power Wiring 115 V 50Z Units a50 8249 ...
Page 110: ...110 Fig 22 Typical Gas Heat Section Size 055 105 Units Shown a48 8413 ...
Page 111: ...111 Fig 23 Component Arrangement Size 030 050 Units ...
Page 112: ...112 Fig 24 Component Arrangement Size 055 070 Units ...
Page 113: ...113 Fig 25 Component Arrangement Size 075 105 Units ...