![Carrier VECTOR 6500 Operation & Service Manual Download Page 78](http://html1.mh-extra.com/html/carrier/vector-6500/vector-6500_operation-and-service-manual_2563864078.webp)
62-11389
3
−
29
3.18 STOPPING UNIT
WARNING
Always place the Main Power switch in the OFF position and turn off the high voltage power sup-
ply before disconnecting the high voltage power plug from the unit.
OFF
STANDBY
ENGINE
unit off
To stop the unit, place the Main Power switch in the OFF
position.
The diesel engine or compressor will stop and the micro-
processor will display “MICRO WILL STOP IN ##
SECONDS”. At the end of the countdown time the Mi-
croprocessor Main Display, MessageCenter, and all in-
dicator LEDs will then turn off.
NOTE
Due to internal processing within the micro-
processor, turning the Main Power switch off
then back on will result in a 4 to 50 second
delay between the display going off and com-
ing back on again.
NOTE
The microprocessor will close the Electronic
Expansion Valve (EVXV) and the CSMV to
0% open before turning off.