3.17 INTELLISET
COOL
DEFROST
ALARM
START‐STOP
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT
CONTINUOUS
APPLES
START‐STOP/
CONTINUOUS
DURING START UP
Observe the MessageCenter during the power up process. If an IntelliSet is running, the name of the IntelliSet
will be displayed for approximately 10 seconds before the unit starts.
DURING OPERATION
Press the SELECT key to view current IntelliSet. You will be prompted to press either the “=” key or the UP or
DOWN ARROW Key to scroll through list of IntelliSets. The current IntelliSet will have either the word ACTIVE or
MODIFIED after it. MODIFIED indicates that one or more of the IntelliSet settings (other than set point) have been
changed. To change MODIFIED to ACTIVE, press = key while the IntelliSet is displayed in the MessageCenter.
SETPOINT
BOX TEMPERATURE
+36.5 F
+34.0
ACTIVE
The Advance Microprocessor offers up to 31 parame-
ters that may be set depending on the product being car-
ried. IntelliSet allows the owner to pre-program specific
product settings into the microprocessor and give the
settings a name. The operator may then call up these
settings by simply selecting the IntelliSet name.
For example: A load of apples may require continuous
operation at 35
°
F (1.7
°
C) with a defrost every 3 hours
while a load of cheese may require the same operation
with set points ranging from 35
°
F to 42
°
F (1.7
°
C to
5.6
°
C) and a load of ice cream requires Start-Stop op-
eration at -22
°
F (-30
°
C) with defrost at 12 hour intervals.
The settings required for each product may be entered
into the microprocessor and then locked so they cannot
be changed. In the case of the cheese, the range of set
points may be locked, leaving the operator the ability to
change the set point within the locked range.
When a load of apples is going to be picked up, the oper-
ator simply selects “APPLES” from the IntelliSet menu;
for cheese, “CHEESE” is selected ; for ice cream, “ICE
CREAM” is selected. With each selection, the micropro-
cessor automatically re-programs the settings to pro-
vide the best temperature control, fuel economy, and
performance for that particular product.
NOTE
The above settings are
examples
of possible
settings. Factory IntelliSets are available from
your authorized Carrier Transicold Truck/Trailer
dealer.
NOTE
IntelliSet #32 is Range Protect, it is designed to
prevent freezing or overheating of non-sensit-
ive cargo by locking the unit is Start-Stop Oper-
ation when the compartment temperature is in
the pre-set range (default range is 32 to 72
°
F, 0
to 32
°
C). Range Protect offers increased power
savings over normal Start-Stop Operation.
The ONLY way to exit from Range Protect is to
select a different IntelliSet.