3.15 FUNCTIONAL PARAMETERS
COOL
DEFROST
ALARM
START‐STOP
ALARM LIST
SELECT
MANUAL
DEFROST
HEAT
CONTINUOUS
START‐STOP/
CONTINUOUS
1. Press the SELECT key until the MessageCenter displays
“PRESS
↑↓
TO VIEW SETTINGS”.
2. By pressing the UP ARROW key, you will move through the Functional
Parameter list beginning at the top or by pressing the DOWN ARROW key,
you will move through the list beginning at the bottom.
3. To change one of the Parameters, bring the Parameter you wish to change into the MessageCenter, and
press = key. “
↑
↓
TO SCROLL, THEN = TO SAVE” will display in the MessageCenter. Pressing either UP or
DOWN ARROW key will display the Parameter selections available for that Function. The MessageCenter
will flash, indicating that a change to the displayed parameter selection has not been entered into memory.
4. Continue pressing UP or DOWN ARROW key until the desired Parameter selection is displayed, then press
the = key. The MessageCenter will stop flashing. The new Parameter selection is now in memory. If the = key
is not pressed within 10 seconds, the MessageCenter will display “FUNCTION NOT CHANGED”. This will
display for 5 seconds, then return to the last Functional Parameter displayed. If no further keys are pressed,
the default display will return in another 10 seconds.
PRESS
↑
↓
TO VIEW SETTINGS
NOTE
The microprocessor may be configured with all of
the Parameters locked or some individual Para-
meters locked. Any Parameter that is displayed
with a padlock symbol cannot be changed from the
keypad.