7
−
100
62-11389
Alarm
NO.
Steps
Alarm/Cause
Corrective Action
227
SERVICE SOON-PM #2 DUE
•
TRIGGER–ON: The Maintenance Hour Meter #2 time has expired.
•
UNIT CONTROL: Alarm Only. Alarm Light will NOT be turned on.
•
RESET CONDITION: Alarm may be manually reset via keypad.
1
Check Unit Maintenance Records
Schedule unit into service facility for
maintenance.
Must be done soon!
2
Perform Maintenance
Perform appropriate engine & unit
maintenance.
Follow instructions on proper maintenance form.
3
Reset Maintenance Hour Meter #2
a. Check that Maintenance Hour
Meter #2 interval is set for your
requirements.
Reset configured Interval if required.
b. Reset Maintenance Hour Meter #2
for the next service interval.
Hour Meter reset is a Functional Parameter.
Follow maintenance interval recommendations in
Section 8.2.
228
SERVICE SOON-PM #3 DUE
•
TRIGGER–ON: The Maintenance Hour Meter #3 time has expired.
•
UNIT CONTROL: Alarm Only. Alarm Light will NOT be turned on.
•
RESET CONDITION: Alarm may be manually reset via keypad.
1
Check Unit Maintenance Records
Schedule unit into service facility for
maintenance.
Must be done soon!
2
Perform Maintenance
Perform appropriate engine & unit
maintenance.
Follow instructions on proper maintenance form.
3
Reset Maintenance Hour Meter #3
a. Check that Maintenance Hour
Meter #3 interval is set for your
requirements.
Reset configured Interval if required.
b. Reset Maintenance Hour Meter #3
for the next service interval.
Hour Meter reset is a Functional Parameter.
Follow maintenance interval recommendations in
Section 8.2.