Safety notes
SPE series
12
Operating manual
12.16
Power line voltage and power line frequency: See type plate
Allowable tolerance of power line voltage: +6%
… −10% of nominal
value
Allowable tolerance of power line frequency: +2%
… −2% of nominal
value
Allowable distortion factor of power line voltage: <=5%
In case your net is infected (e.g. by using thyristor controlled
machines) anti-interference measures have to be taken. You can use
one of the following possibilities:
Provide separate power supply to our print modules.
In case of problems please connect capacity-decoupled isolation
transformer or similar interference suppressor in front of our print
modules.
Emitted interference according to EN 61000-6-4: 08-2002
Interference voltage to wires according to EN 55022: 09-2003
Interference field power according to EN 55022: 09-2003
Immunity to interference according to EN 61000-6-2: 03-2006
Stray radiation against discharge of static electricity according to
EN 61000-4-2: 12-2001
Electromagnetic fields according to EN 61000-4-3: 11-2003
Fast transient burst according to EN 61000-4-4: 07-2005
Surge according to EN 61000-4-5: 12-2001
High-frequency tension according to EN 61000-4-6: 12-2001
Voltage interruption and voltage drop according to EN 61000-4-
11: 02-2005
NOTICE!
This is a machine of type A. This machine can cause
interferences in residential areas; in this case it can be required
from operator to accomplish appropriate measures and be
responsible for it.
EN 415-2 - Safety of pachaging machines
EN 60204-1:2006 - Safety of machinery - Electrical equipment of
machines - Part 1
Technical data of
power supply
Anti-Interference
measures
Stray radiation and
immunity from
disturbance
Machine safety