Function menu
SPE series
58
Operating manual
12.16
Press key
to arrive at the next menu item.
TRB = Transfer ribbon advance warning:
Before the end of transfer ribbon, a signal is send by the control
output.
Warning diameter:
Setting of transfer ribbon acvance warning diameter.
In case you enter a value in mm then a signal appears via control
output when reaching this diameter (measured at transfer ribbon roll).
Ribbon advance warning mode:
Warning:
When reaching the transfer ribbon advance warning
diamter, the corresponding I/O output is set.
Reduced print speed:
Speed on which the printing speed is to be
reduced.
Error:
The printing system stops when reaching the transfer ribbon
advance warning diameter with the message 'too less ribbon'.
Reduced print speed:
Setting of the reduced print speed in mm/s. This can be set in the
limits of the normal print speed.
Press key
to arrive at the next menu item.
Zero point adjustment:
Indication of value in 1/100 mm.
After replacing the printhead - the print cannot be continued at the
same position on the label, the difference can be corrected.
NOTICE!
The value for zero point adjustment is set ex works. After
replacing the printhead, only service personnel are allowed to set
this value anew.