In case no password is defined res. the password protection is not
activated, all functions can be used. In the function menu you will find
the menu item "Password", where the password can be entered and
the password protection activated.
Press key
as long as to the 'Password' menu.
Press key
to confirm the selection.
Meaning of abbreviations:
F
Function menu
MC
Memory Card
D
Print functions
In case the password protection is active, but the function menu is not
protected, the password
(4-digit number between 0000 and 9999) has to be entered first, so
the above shown display appears. Now changes can be done. In the
first line the user can define the password (4-digit number).
Press key
to switch to the next.
Press key
and
to activate/deactivate the password protection
(yes/no).
Press key
to change to the second line.
Press key
and
to block/release individual function groups.
(Press key
and
to change from one group to the next one.)
F:
Function menu
0...open
1...locked
MC:
Memory Card
0...open
1...only reading access
2...access blocked
D:
Printer guiding
0...open
1...open
2...no manual print release
In case the user wants to perform a blocked function, he has to enter
the valid password first.
The entered password has to be confirmed with
E
. In case the correct
password has been entered the desired function can be performed. If
the entered password was invalid no error message appears but the
main menu will be displayed.
Define password
Activate blocked
function: