Error Correction
Compa II
96
Operating manual
03.20
Error message
Cause
Remedy
16
Unknown mask
Transferred mask statement is
invalid.
Check sent data.
Check connection PC - printer.
17
Missing ETB
No end of data found.
Check sent data.
Check connection PC - printer.
18
Invalid character
One res. several characters of
the bar code is res. are not
valid.
Change bar code data.
Change font.
19
Invalid statement
Unknown transferred data
record.
Check sent data.
Check connection PC - printer.
20
Invalid check digit
For check digit control the
entered res. received check
digit is wrong.
Calculate check digit anew.
Check code data.
21
Invalid SC code
Selected SC factor is invalid for
EAN res. UPC.
Check SC factor.
22
Invalid number of
digits
Entered digits for EAN res.
UPC are invalid
< 12; > 13.
Check number of digits.
23
Type check digit
Selected check digit calculation
is not available in the bar code.
Check calculation of check
digit.
Check bar code type.
24
Invalid extension
Selected zoom factor is not
available.
Check zoom factor.
25
Offset sign
Entered sign is not available.
Check offset value.
26
Offset value
Entered offset value is invalid.
Check offset value.
27
Printhead
temperature
Printhead temperature is too
high.
Defective printhead sensing
device.
Reduce contrast.
Change printhead.
28
Cutter error
With cut an error occurred.
Paper jam.
Check label run.
Check cutter run.
29
Invalid parameter
Entered data do not correspond
to the characters allowed from
the application identifier.
Check code data.
30
Application
Identifier
Selected application identifier is
not available in GS1-128.
Check code data.
31
HIBC definition
Missing HIBC system sign.
Missing primary code.
Check definition of HIBC code.
32
System clock
Real Time Clock function is
selected but the battery is
empty.
Defective RTC.
Change battery.
Change RTC component.
Summary of Contents for COMPA II
Page 1: ...COMPA II Operating Manual ...
Page 10: ...Introduction Compa II 10 Operating manual 03 20 ...
Page 16: ...Safety Notes Compa II 16 Operating manual 03 20 ...
Page 26: ...Technical Data Compa II 26 Operating manual 03 20 ...
Page 30: ...Installation Compa II 30 Operating manual 03 20 ...
Page 42: ...Load Media Compa II 42 Operating manual 03 20 ...
Page 64: ...Function menu Compa II 64 Operating manual 03 20 ...
Page 104: ...Error Correction Compa II 104 Operating manual 03 20 ...
Page 112: ...Environmentally Friendly Disposal Compa II 110 Operating manual 03 20 ...