background image

Manuale per il tecnico

Manuel destiné au technicien

Handbuch für den Techniker

Technician’s Manual

Manual para el tecnico

Manual para o técnico

10

CLASSE 10 

USB / S /

 

RE

USB / S / RE

Summary of Contents for CLASSE 10

Page 1: ...Manuale per il tecnico Manuel destin au technicien Handbuch f r den Techniker Technician s Manual Manual para el tecnico Manual para o t cnico 10 CLASSE 10 USB S RE USB S RE...

Page 2: ...ungen die in diesem Handbuch beschrieben werden d rfen nur von ausgebildeten Technikern durchgef hrt werden GB The interventions and the programming procedures described in this manual may only be car...

Page 3: ...5 2 1 7 Regeneration of the filter resins 5 2 1 8 Preventive maintenance 5 2 1 9 Boiler sensor 5 2 1 10 Level sensor 5 2 1 11 Error codes log 5 2 1 12 First time start up 5 2 1 13 Technical menu acce...

Page 4: ...ically after 3 minutes if the set temperature has not yet been reached 2 1 Renewal the millk nozzle To increase the quantity of frothed milk change the standard emulsion nozzle indicated by a notch re...

Page 5: ...ispensing from the groups for 30 sec Pauses for 30 sec Keeping esc pressed for 2 seconds during the cycle the current washing phase will stop and the next phase will take place It is advisable to alwa...

Page 6: ...ess or To enter in a submenu press enter while to quit press esc When a submenu is accessed the editable value is displayed and changes can be made to it by pressing on the or keys If you make changes...

Page 7: ...ing of the 3 4 tea keys provi des for different water temperatures ranging between 85 C and approx 60 C During dispensing the pump is activated It is also possible to set a dispensing option providing...

Page 8: ...hat it is not displayed 5 2 1 9 Boiler sensor Setting the type of boiler pressure sensor Temperature sensor Pressure transducer default 5 2 1 10 Level sensor Sets the type of boiler water level sensor...

Page 9: ...MAX level 5 2 4 2 No milk frothing Setting of the milk s final temperature and emulsion grade on a scale from 0 to MAX If set at level 0 the milk is only heated Increasing the emulsion level will incr...

Page 10: ...repeated every hour until it is reset Please make the service time if the function is enabled and the set values have been reached this message will be then repeated every hour until it is reset SOLE...

Page 11: ...The boiler safety devices can be reset by switching the machine OFF and then back ON again 8 THE CUP WARMER By pressing the relative button the display shows the following Depending on the darkened se...

Page 12: ...g the relative error code on screen which will come flashing on alternatively to the customisation logos Because they are not serious these errors will allow the machine to keep running We nevertheles...

Page 13: ...84 3 Edificio Trade 08028 Barcelona Spain Tel 34 902 884 275 Tel 34 934 923 414 Fax 34 93 496 57 01 www rancilio com info rancilio es USA Rancilio North America Inc 8102 S Lemont Rd 1200 Woodridge IL...

Page 14: ...www rancilio com Cod 46900147 REV 03 2008...