Compa II
Maintenance and Cleaning
03.20
Operating manual
89
9.4 Clean the Label Photocell
CAUTION!
Label photocell can be damaged!
Do not use sharp or hard objects or solvents to clean
the label photocell.
The label photocell can be soiled with paper dust. This may affect the
label scanning.
Figure 20
1. Turn the lever (1) counter clockwise to lift up the printhead.
2. Remove labels and transfer ribbon from the label printer.
3. Remove the hexagonal wrench (5) from its retainer.
4. Press the latch (3) and slowly pull the label photocell outwards via
the tab (4). Ensure that the label sensor cable is not tensioned by
this.
5. Clean the label sensor and sensor units (2) with brush or cotton
swab soaked in pure alcohol.
6. Push the label photocell back via tab (3) and set it (see section
Set the label photocell on page 32).
7. Push the hexagonal wrench (5) into retainer.
8. Reload labels and transfer ribbon (see chapter 5 Load Media on
page 31).
Compa II 103 T, 104,