Compa II
Technical Data
03.20
Operating manual
23
Identification Pin Description / Function
+ 5 VDC
EXT
25
5 Volt DC output for external use. Max. 1 A.
This voltage is provided from direct print module and can be used e.g. as
control voltage. Never apply any external voltage to this output.
+ 24 VDC
EXT
26
24 Volt DC output for external use. Max. 1 A.
This voltage is provided from direct print module and can be used e.g. as
control voltage. Never apply any external voltage to this output.
Plug Connector
Type
D-Sub connector High Density
26-pin. / connector
Manufacturer
W+P-Products
Reference number
110-26-2-1-20
Output Voltages (connected with GND-PE)
+ 24 V / 1 A
Fuse: Polyswitch / 30 V / 1 A
+ 5 V / 1 A
Fuse: Polyswitch / 30 V / 1 A
Port 1 - 15
Input
Voltage
5 VDC … 24 VDC
Impedance
47Ω + (100nF || 10 kΩ)
Output
Voltage
5 VDC … 24 VDC
Impedance
47Ω + (100nF || 10 kΩ || 47Ω)
Current max.
High +15 mA
Low -15 mA
Port 16
Input
Voltage
5 VDC … 24 VDC
Impedance
100nF || 10 kΩ
Output
Voltage
5 VDC … 24 VDC
Impedance
100nF || 10 kΩ
Current max.
High +500 mA (Darlington BCP56-16)
Low - 500 mA (Darlington BCP56-16)
Optocoupler
Output
TCMT4106, CTR 100 % - 300 %, Vishay or
TLP281-4(GB), CTR 100 % - 600 %,
Toshiba
Input
TCMT4106, CTR 100 % - 300 %, Vishay or
TLP281-4(GB), CTR 100 % - 600 %,
Toshiba
Input
Option 2nd LED
TCMT4600, CTR 80 % - 300 %, Vishay or
TLP280-4, CTR 33 % - 300 %, Toshiba
Technical data
Summary of Contents for COMPA II
Page 1: ...COMPA II Operating Manual ...
Page 10: ...Introduction Compa II 10 Operating manual 03 20 ...
Page 16: ...Safety Notes Compa II 16 Operating manual 03 20 ...
Page 26: ...Technical Data Compa II 26 Operating manual 03 20 ...
Page 30: ...Installation Compa II 30 Operating manual 03 20 ...
Page 42: ...Load Media Compa II 42 Operating manual 03 20 ...
Page 64: ...Function menu Compa II 64 Operating manual 03 20 ...
Page 104: ...Error Correction Compa II 104 Operating manual 03 20 ...
Page 112: ...Environmentally Friendly Disposal Compa II 110 Operating manual 03 20 ...