Stray Radiation and Immunity from Disturbance
Emitted interference according to EN 61000-6-3: 2007 industrial sector
•
Interference voltage to wires according to EN 55022/AC: 2011-10
•
Interference field power according to EN 55022/AC: 2011-10
•
System perturbation according to EN 61000-3-2: 2014-08
•
Flicker according to EN 61000-3-3: 2013-08
Immunity to interference according to EN 61000-6-2: 2008 industrial sector
•
Stray radiation against discharge of static electricity according to EN 61000-4-2: 1995
•
Electromagnetic fields according to EN 61000-4-3: 2002
•
Fast transient burst according to EN 61000-4-4: 2004
•
Surge according to EN 61000-4-5: 2014-08
•
High-frequency voltage according to EN 61000-4-6: 2014-02
•
Magnetic field with energy frequency according to EN 61000-4-8: 1993
•
Voltage interruption and voltage drop according to EN 61000-4-11: 2004
NOTICE!
This is a machine of type A. This machine can cause interferences in residential areas; in this case it can be
required from operator to accomplish appropriate measures and be responsible for it.
Connecting Lines to External Machines
All connecting lines have to be guided in shielded lines. Shielding has to be connected on both sides to the corner shell.
It is not allowed to guide lines parallel to power lines. If a parallel guiding cannot be avoided a distance of at least 0.5 m has to
be observed.
Temperature of lines between:
−15 … +80 °C.
It is only allowed to connect devices which fulfil the request 'Safety Extra Low Voltage' (SELV). These are generally devices
which are checked corresponding to EN 60950/EN 62638-1.
Installation of Data Lines
The data cables must be completely protected and provide with metal or metallised connector housings. Shielded cables and
connectors are necessary, in order to avoid radiant emittance and receipt of electrical disturbances.
Allowable lines
Shielded line:
4 x 2 x 0,14 mm² ( 4 x 2 x AWG 26)
6 x 2 x 0,14 mm² ( 6 x 2 x AWG 26)
12 x 2 x 0,14 mm² (12 x 2 x AWG 26)
Sending and receiving lines have to be twisted in pairs.
Maximum line length:
with interface V 24 (RS232C) - 3 m (with shielding)
with parallel interface - 3 m (with shielding)
with USB - 3 m
with Ethernet - 100 m
Air Convection
To avoid inadmissible heating, free air convection has to be ensured.
Summary of Contents for Compa II 103/8 T
Page 1: ...COMPA II Quick Reference Guide Central Europe ...
Page 4: ......
Page 5: ...Kurzanleitung und Hinweise zur Produktsicherheit Deutsch ...
Page 34: ......
Page 35: ...Instrucciones abreviadas y recomendaciones de seguridad Español ...
Page 64: ......
Page 65: ...Guide de référence rapide et de sécurité des produits Français ...
Page 94: ......
Page 95: ...Quick reference guide and product safety English ...
Page 124: ......
Page 125: ...Guida rapida e sicurezza del prodotto Italiano ...
Page 154: ......
Page 155: ...Português 155 Guia rápido e informações sobre a segurança do produto Português ...
Page 184: ......
Page 185: ...Kısa kullanım kılavuzu ve ürün güvenliğiyle ilgili uyarılar Türkçe ...